If the intention is to not install a permanently open vent to the room, or to install an
AirSmart system in its place, then the installer must follow the procedure in Hetas
Technical Note TN_0020 to confirm that the supply of air will be sufficient.
vi.
Minimum distance to combustible materials
A
1000 mm From the front of the stove
B
700 mm
Behind the stove
C
700 mm
To each side of the stove
When the stove is installed, all fire protection regulations and
the minimum distances specified must be kept to.
It is also possible to heat shield combustible materials if the
stove must be installed at a closer distance than specified
here. For heat shielding refer to the guidance detailed below.
For further information on heat-shielding please refer to the “Firepower Heat
Shielding Guide” which can be found on the downloads section of the
www.firepower.co.uk website. This gives in depth guidance on heat-shielding
combustible materials using metal or Thermalux sheets.