![Woodfire Passiv Скачать руководство пользователя страница 24](http://html.mh-extra.com/html/woodfire/passiv/passiv_operation-and-installation-manual_994875024.webp)
heat from your thermal store.
•
Check the function and setting of the pump control and the load
valve.
•
Is the circulation pump running?
•
Vent the boiler and check the system pressure.
•
The valve may have become stuck or there may be detritus
inside it. There is a red button on the valve – when pressed
down this can be used to test that it works. Press down a couple
of times on this red button and this may re-seat the valve.
Noises in the heat exchanger / air
in the heating system
•
0
The overheat safety valve drain is
dripping
•
The valve may have become stuck or there may be detritus
inside it. There is a red button on the valve – when pressed
down this can be used to test that it works. Press down a couple
of times on this red button and this may re-seat the valve.
•
Check the seat of the connection seals and the piston (see
instructions for the overheat safety valve).
•
Add a filter in the cold water inlet in front of the overheat safety
valve.
The radiators stay cold
•
The heating system takes time to pass the heat to the radiators.
•
Has the heating system been balanced?
•
Check that the circulation pump is working.
The combustion chamber lining is
black
•
Check the combustion chamber, the baffle deflectors and the
chimney for blockages.
•
The moisture content of the wood is too high. Only use wood
with a moisture content of 20% or less.
•
Check that the stove is receiving sufficient combustion air.
15. General warranty conditions
The warranty cover is effective from when the unit is handed over to the buyer.
In case the commissioning does not take place within 3 months from the date of purchase
then the warranty period starts on the day of purchase of the product, which must be
demonstrated by proof of purchase such as a sales receipt or paid invoice from the seller.
Woodfire declines all liability for any accidents due to failure to observe the specifications
contained in the use and maintenance manual accompanying the device. Furthermore,
Woodfire declines all liability deriving from improper use of the product by the user
(including heat-shock, overload or misuse of the firebox), unauthorised modifications and/
or repairs, and the use of non-original spare parts or spare parts not designed for use on
this model.
24