Flue termination heights must comply with the requirements of Document J of the Building
Regulations.
Adequate provision must be made so that all internal parts of the chimney can be cleaned.
This stove is not suitable for use on a shared chimney.
Recommendations:
• Working level of chimney: min. 5 meters
• Maximum diameter of flue 160 mm
• Any existing chimney should be examined by an expert
7.
Connecting the stove into the heating and hot water system
Connecting the stove to a central heating and hot water system must be carried out by a
suitably qualified and experienced heating engineer. All safety requirements must be
adhered to and any safety components that need to be checked or serviced must be made
accessible. All protective caps on the connections must be removed during assembly. All
plumbing connections must be connected according to their intended use.