RFG Oven Installation and Operation Manual
Hourly Natural Gas BTU input rates
for Wood Stone RFG gas ovens
Model
Hourly BTU Input Rate
WS-MS-4-RFG-NG 68,000
WS-MS-5-RFG-NG 105,000
WS-MS-6-RFG-NG 105,000
WS-MS-7-RFG-NG 123,000
Hourly Propane BTU input rates
for Wood Stone RFG gas ovens
Model
Hourly BTU input Rate
WS-MS-4-RFG-LP 60,000
WS-MS-5-RFG-LP 94,000
WS-MS-6-RFG-LP 94,000
WS-MS-7-RFG-LP 142,000
Wood Stone recommends that the appliance’s individual shutoff valve
(supplied by others) be left readily accessible. Wood Stone also
recommends that inspection and maintenance of the burner and gas
piping connections of this appliance be performed at regularly
scheduled intervals and only by professional gas appliance service
agencies.
Gas Code Limitations
The installation of this appliance must conform with local codes, or in the absence of
local codes, with the National Fuel Gas Code, ANSI Z223.1, The Natural Gas installation
Code CAN/CGA-B149.1 or the Propane Installation Code, CAN/CGA-B149.2, as applicable
including:
The appliance and its individual shutoff valve (supplied by others) must be disconnected
from the gas supply piping system during any pressure testing of that system at test pressures
in excess of 1/2 psi (3.45 kPa).
The appliance must be isolated from the gas supply piping system by closing its individual
manual shutoff valve (supplied by others) during any pressure testing of the gas supply piping
system at test pressure, equal to or less than 1/2 psi (3.45 kPa).
GAS SPECIFICATIONS