Debarker Installation
Lower Harness Installation
Debarker Installation
MKI96DB98doc011711
2-18
2
6.
Connect the red drive motor wire to the red lower harness wire. Connect the black drive
motor wire to the black lower harness wire.
7.
Wrap the wire connections with electrical tape. Route the lower harness through the cable
clamp on the vertical frame tube. Be sure to retain the tubing loop to allow the debarker
arm to move and pivot in full range and also to prevent undue wire stress from sharply
bent wires.
See Figure 2-17.
FIG. 2-17
3H0236
Route harness
through
cable clamp
Wrap connections