Debarker Installation
Lower Harness Installation
2
2-19
MKI96DB98doc011711
Debarker Installation
8.
Route the cable down through the bottom cable clamp and to the blade motor terminals.
9.
Route the warning bell wires along the cable and secure with a tie wrap. Use a provided
wire tie to secure the bell wires to the lower harness approximately 3" from the motor ter-
minals as shown.
See Figure 2-18.
10.
Next, connect the lower harness wires to the terminals at the bottom of the debarker cut-
ting motor. The harness tubing and wires will be longer than necessary (to allow for differ-
ences in routing). Cut excess length.
11.
Route the black motor wire from the lower harness and the black wire from the warning
bell through one of the provided rubber boots.
FIG. 2-18
Route cable and
bell wires to
motor terminals
Route cable
through cable clamp
Secure bell wires to
cable with tie wrap
3H0237