![Wood-mizer LMS-HPR Скачать руководство пользователя страница 38](http://html1.mh-extra.com/html/wood-mizer/lms-hpr/lms-hpr_safety-installation-operations-and-service_994550038.webp)
Electrical Information
Electrical Components
5
5-1
LMS99doc032619
Electrical Information
SECTION 5 ELECTRICAL INFORMATION
5.1
Electrical Components
Component
Wood-Mizer Part No.
Description
D1
024123
1
1
Added Rev. C.00 to protect power feed control circuit. Use kit 050805 to retrofit earlier revisions.
Diode Assembly, Inductive Kick Protection
F1
024555
Fuseholder, In-Line 3-20 Amp ATC w/Cover
024150-2
Fuse, 2 Amp ATO Blade Light Grey
F2
024555
Fuseholder, In-Line 3-20 Amp ATC w/Cover
024150-4
Fuse, 4 Amp ATO Blade Pink
L1
E20483
Light, Green 12V .187 Tabs
P1
033492
Pump Assembly, LubeMizer (Includes D1)
R1
024591
Resistor Assembly, 47K Yellow Lube Timer
SW1
024588
Switch, 15 Amp Toggle
T1
024530
Timer, Repeat Cycle 12VDC 1A .2-60 Seconds
VR1
024590
Potentiometer Assembly, 500K 2W 10% CP Panel Mount