![Wood-mizer LMS-HPR Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/wood-mizer/lms-hpr/lms-hpr_safety-installation-operations-and-service_994550011.webp)
LubeMizer Installation
Pump Installation And Wiring (All LT30/LT40 Sawmills)
LubeMizer Installation
LMS99doc032619
1-8
1
3.
Remove all 3/8" water lube hose from the mill.
4.
Remove the water bottle and fuel tank from the mill and set aside.
5.
For Super Mills Only,
disconnect the red and black sawmill harness wires from the exist-
ing water solenoid valve. Remove the valve from the mill.
NOTE:
This step also applies to
Standard mill owners who have installed Water Solenoid Valve Kit 016141.
If the sawmill is not equipped with a water solenoid valve, the wires for the LubeMizer
option are stored underneath the water tank tray. Locate wires #19 and #20 and remove
any electrical tape to expose the terminals on the end of the wires.
6.
Install the lube pump assembly to the mill as shown using the existing fuel/water mount-
ing plate bolts and nuts.
See Figure 1-6.
NOTE:
On older revision mills, the front bolt will be shorter. Replace this shorter bolt with
the supplied longer, 1/4-20 x 3/4" bolt.
FIG. 1-6
Pump Assembly
1/2” Hose Clamp
Mounting Nut (2)
Wire Tie To Fuel Line
Filter
5/8” Hose Clamp
Wire Tie To Fuel Line
3/8” Hose (14” Length)
3H0749