SETUP & OPERATION
Moulder Setup
Operation
EGdoc030112
4-2
4
IMPORTANT!
When starting the machine for the first time, check that
main motor rotation direction is as indicated by the arrow located on
the motor body (fan guard). If the rotation direction is incorrect, invert
the phases in the phase inverter in the power socket (electric box).
Setting the phases in the phase inverter correctly will ensure correct
rotation directions of all moulder motors.
DANGER!
To check the cutter rotation direction, look at the motor fan
when the motor is starting or stopping through the inspection window
shown below. Do not for any reason check the rotation direction by
touching the cutter using any tool or a piece of wood. Doing so may
result in serious injury or death.
IMPORTANT!
It is recommended that a 30mA Ground Fault Interrupter
(GFI) be used.
The following setup procedure should be performed whenever the moulder is moved or
reassembled.
If sawing problems occur and misalignment is suspected, see
complete alignment instructions.
1.
Adjust the frame legs so the moulder appears level. If the moulder is on soft ground, use shims under
the legs if necessary.
2.
Run a string from the front bed rail to the rear bed rail near the operator’s side of the frame. Place
identical spacers between the string and the front and rear bed rails. Measure the distance between
the string and the other bed rails. Adjust the frame legs until all bed rails measure the same distance
from the string.
3.
Loosen the auxiliary bed rail bolts and adjust the rail so it is the same distance from the string as the
main bed rails. Retighten the bolts.
FIG. 4-0
!
Inspection
Window
Remove the
Inspection
Window Cap
!
Содержание A1.01
Страница 1: ...Table of Contents Section Page Table of Contents SW 07doc0301121...
Страница 2: ......