ELECTRONIC TEMPERATURE CONTROL (E.T.C.):
Function:
(Factory Settings below)
• The E.T.C. monitors and controls the WoodMaster water temperature by controlling the draft and draft fan.
• During normal operation (adequate wood supply) the controller will turn off the draft and draft fan when the water
reaches 170° F (Set) and will turn on the draft and draft fan when the water falls 10° F (Hy, see page 20).
• During shut down (low wood supply) or when the water falls to 120° F (ALL, see page 20) the controller will shut off
the draft and draft fan. At this time, the WoodMaster will need to be filled with wood and the ETC will need to be reset.
(See page 13)
Energy Start Shut-Down (LA):
•
This function shuts down the WoodMaster draft and draft fan when not in use and back-up system is operating
(Example: if gone for the weekend, wood firing furnace runs out of wood and back-up system takes over). To restart
the WoodMaster, simply push the Set Button.
Start Up / Reset
• The first time the WoodMaster is powered up or when it has shutdown, the controller display will flash “LA” two
times and then display the water temperature for two seconds and then start over. This is normal and indicates the
system has shut down because the water is at or below 120° F.
• To start up (or reset) your WoodMaster, press the set button one time. The display will indicate “rSt” (reset) and after
1 to 2 seconds, the draft will open and the draft fan will turn on. The display will continue to flash “LA” and the water
temperature will be displayed until the water temperature reaches 140° F (ALL + 20). After water temperature
reaches 140° F, only the water temperature will be displayed until the water temperature falls to 120° F.
•
Note:
The fan switch must be in the on position.
•
Note:
Fan switch can be shut off when loading or for servicing.
Parameter Description and Factory Settings:
• Set (Set Point) - 170° F
• Hy (Differential) - 10° F
• ALL (Low Alarm) - 120° F
How To:
•
View Set Point
— Push and immediately release the set key, display will indicate set point and will return to water
temperature after 5 seconds.
• Change the Set Point — Push and hold the set key until the set point is displayed, change the value using the up and
down arrows, and press the set key. The set point will flash a few times and then the display will return to water tem
-
perature.
• Change Hy or ALL — Push and hold the set and down arrow keys at the same time until Hy is displayed. Using
the up and down arrows, select the parameter to be changed (Hy or ALL), push the set key once (value of parameter
should be displayed), use arrows to change value, and push the set key (value should flash a few times). After 10-15
seconds the display will change back to water temperature.
Green Float Light:
• Green light on: Water level O.K.
• Green light off: Water level low, add water.
Light Switch:
Operates lights.
Fan Switch:
The fan switch must be on during normal operation, but may be turned off to fill furnace or for maintenance.
E.T.C. Guide