When the above checks have been completed partially depress the control knob and turn to “OFF”.

If the above checks are satisfactory, continue with the installation.  If not, check the control and ignition circuitry and components as
described in the servicing section of this manual.

CHECK REFERENCE PRESSURE

The appliance is pre-set to give the correct heat input at the inlet pressure shown in the Technical Specification section of this manual.  No
adjustment is necessary.  Check the burner pressure by fitting a pressure gauge at the test point.  The test point is on the pipe situated below
the bottom right corner of the burner unit.  Check the pressure with the appliance alight and set at maximum output.

After checking, turn off the appliance.  Remove the pressure gauge and replace the test point sealing screw.  Relight the appliance.  Turn to
the maximum output position and test around the sealing screw for gas soundness with a suitable leak detection fluid.

FITTING THE CERAMICS

Prior to fitting the ceramics, assemble the
Burner tray trim (packed loose) to the front
of the burner tray trim. Simply hook the
trim over the front flanges of the burner
tray and push downwards.

Fit the ceramic rear wall (figures 8 & 9).
The featheredge of the ceramic rear wall
must be at the top

.

Place the front base coal in the
burner compartment so that it
rests on the ledges at the sides
and front.  

Pull the coal

forward so that it is
immediately behind the front
rim of the burner
compartment.

  (See Fig 10 &

11).

 

Figure 9 Ceramic rear wall position

 

Figure 8 Ceramic rear wall & Bracket

fixing

     

 

Figure 11 Front Base Coal in Position

 

 

Figure 10 Front Base Coal Positioning

Содержание The Gallery BR218C1

Страница 1: ...Inset Live fuel Effect Engine for use with The Gallery Fire Collection Model BR218C1 INSTALLATION AND SERVICING INSTRUCTIONS Please keep in a safe place for future reference 600B654 01...

Страница 2: ...cal call rates apply In the Republic of Ireland call 353 183 75114 As supplied this appliance is for use with natural gas G20 When converted using conversion kit no 591149 this appliance is for use wi...

Страница 3: ...ention 8 Floor Sealing 8 Preliminary Burner Checks 8 Check Reference Pressure 9 Fitting the Ceramics 9 Full Operating Checks 11 Recheck Control Settings 11 Check for Spillage 11 Flame Supervision Spil...

Страница 4: ...olidation Regulations issued by the Scottish Development Department c All relevant codes of practice d The relevant parts of the current editions of the following British Standards BS 715 BS 1251 BS 1...

Страница 5: ...0 75mbar 6 8 0 3in w g 36 2 0 75mbar 14 53 0 3in w g Gas Connection 8mm pipe 8mm pipe Burner Injector Bray Cat 18 Size 360 Bray Cat 18 Size 170 Pilot Atmosphere Sensing Device SIT Ref OP9030 SIT Ref O...

Страница 6: ...well as the current edition The flue blocks must have a minimum width not less than 63mm and a cross sectional area not less than 13 000mm2 Older editions of BS1289 required a cross sectional area of...

Страница 7: ...for any evidence of mishandling which might affect the performance Each unit is flame tested before it leaves the factory and as a result there may be slight discoloration around the burner ports The...

Страница 8: ...ose to the inner face of the surround to the fire front casting to be correctly positioned The pipe should pass through the cutout in the casting side For right hand side connection The supply pipe wi...

Страница 9: ...urn off the appliance Remove the pressure gauge and replace the test point sealing screw Relight the appliance Turn to the maximum output position and test around the sealing screw for gas soundness w...

Страница 10: ...he four valleys of the front coal Place the left side coal so that the customer will be able to see the pilot flame Figures 14 15 Place the three remaining medium size coals behind and approximately m...

Страница 11: ...this check with the appliance fully installed with the ceramic fuel effects and front surround in position Close all doors and windows in the room containing the appliance Light the appliance and tur...

Страница 12: ...of this system shown in the users instructions under Operating the Fire Advise that if the fire goes out for any reason wait at least three minutes before relighting Stress that if the monitoring sys...

Страница 13: ...f necessary remove the gauze and the gasket beneath it If necessary fit a new gasket below the gauze Clean and replace the gauze Fit a new combination gasket below the plaques Push the gasket ends inw...

Страница 14: ...Remove the plug rotating slightly while pulling Clean and grease the plug lightly with suitable grease Do not apply excessive grease Particularly make sure that the gas ports in the tap are not restr...

Страница 15: ...e Appliances 571709 B Gas tap spark generator 1 569429 C Spark generator 1 521069 D Control knob 1 545979 E Pilot unit For Natural Gas Appliances 1 540979 Pilot unit For Propane Appliances 566929 F Bu...

Страница 16: ...SO 9001 quality system accepted by the British Standards Institute All Wonderfire gas appliances must be installed by a competent Corgi Registered Installer in accordance with our Installer Guide If i...

Отзывы: