1. APPLIANCE DATA
This product uses fuel effect pieces, burner compartment walls and gaskets containing Refractory Ceramic Fibres (RCF), which are
man-made vitreous silicate fibres. Excessive exposure to these materials may cause temporary irritation to eyes, skin and respiratory
tract. Consequently, it makes sense to take care when handling these articles to ensure that the release of dust is kept to a minimum.
To ensure that the release of fibres from these RCF articles is kept to a minimum, during installation and servicing we recommend that
you use a HEPA filtered vacuum to remove any dust and soot accumulated in and around the fire before and after working on the fire.
When replacing these articles we recommend that the replaced items are not broken up, but are sealed within a heavy duty polythene
bag, clearly labelled as RCF waste. This is not classified as “hazardous waste” and may be disposed of at a tipping site licensed for the
disposal of industrial waste. Protective clothing is not required when handling these articles, but we recommend you follow the normal
hygiene rules of not smoking, eating or drinking in the work area and always wash your hands before eating or drinking.
This appliance does not contain any component manufactured from asbestos or asbestos related products.
The appliance data label is on a plastic tie below the burner and is visible when the bottom front cover is removed.
Gas
Natural (G20)
Propane (G31)*
Inlet Pressure
20mbar
37mbar
Input - Max. (Gross)
6.0kW (20,500Btu/h)
6.1kW (20,800Btu/h)
Input - Min. (Gross)
2.2kW (7500Btu/h)
3.6kW (12280Btu/h)
Output - Max.
3.5kW (11,900Btu/h)
3.6kW (12,280Btu/h)
Output - Min
1.1kW (3750Btu/h)
1.8kW (6140Btu/h)
Burner Test Pressure (Cold)
17.0±0.75mbar (6.8±0.3in
w.g.)
35.6±0.75mbar
(14.3±0.3in w.g.)
Gas Connection
8mm pipe
8mm pipe
Burner Injector
Bray Cat. 18 Size 360
Bray Cat. 18 Size 170
Pilot & Atmosphere
Sensing Device
SIT Ref. OP9030
SIT Ref. OPLPG9222
Ignition
Piezo Electric. Integral
with Gas Tap
Piezo Electric. Integral
with Gas Tap
Aeration
Non-adjustable
Non-adjustable
*
When converted using Kit 591149
2. GENERAL INSTALLATION REQUIREMENTS
2.1
For the user’s protection, in the United Kingdom it is the
law that all gas appliances are installed by competent persons
in accordance with the current edition of the Gas Safety
(Installation and Use) Regulations. Failure to install the
appliance correctly could lead to prosecution. The Council for
the Registration of Gas Installers (CORGI) requires its
members to work to recognised standards.
The Confederation for the Registration of Gas Installers
(CORGI) requires its members to work to recognised
standards.
The installation must be in accordance with these instructions.
In the United Kingdom the installation must also be in
accordance with:
a)
All the relevant parts of local regulations.
b)
The current edition of the Building Regulations issued
by the Department of the Environment and the Welsh Office
or the Building Standards (Scotland) (Consolidation)
Regulations issued by the Scottish Development Department.
c)
All relevant codes of practice.
d)
The relevant parts of the current editions of the
following British Standards:-
BS 715
BS 1251
BS 1289 Part 1
BS 1289 Part 2
BS 4543 Part 2
BS 5440 Part 1
BS 5440 Part 2
BS 5871 Part 2
BS 6461 Part 1
BS 6891
BS 8303
In the republic of Ireland the installation must also conform to
a) The relevant parts of: The current edition of: IS 813
b)
All relevant national and local rules in force.
2.2
If the appliance is intended to be installed to a chimney
which was previously used for solid fuel, the flue must be
swept clean prior to installation. All flues should be inspected
for soundness and freedom from blockages
2.3
The minimum effective height of the flue must be 3m
.
2.4
Any chimney dampers or restrictors should be removed.
If removal is not possible they must be fixed in the open
position.