background image

Revised: 14/11/2011 

 

    Printed: 20/03/2013 

1

 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

SAVE THESE INSTRUCTIONS 

 

 

INSTALLATION  

&  

OPERATING INSTRUCTIONS

 

 
 
Serial Number of Heater: ____________ Model: ___________________ 

 

 

 

ARROW

  WOOD HEATERS ARE AUSTRALIAN OWNED AND MANUFACTURED BY 

SHAMIC SHEETMETAL

SHAMIC SHEETMETAL

SHAMIC SHEETMETAL

SHAMIC SHEETMETAL

 

(AUST.) PTY. LTD. 

PO BOX 8, KILSYTH, VIC. 3136 

PH: 03 9737 5300 FAX: 03 9761 6455 

www.shamicheating.com.au 

 

 

 

Содержание 1600

Страница 1: ...IONS Serial Number of Heater ____________ Model ___________________ ARROW WOOD HEATERS ARE AUSTRALIAN OWNED AND MANUFACTURED BY SHAMIC SHEETMETAL SHAMIC SHEETMETAL SHAMIC SHEETMETAL SHAMIC SHEETMETAL AUST PTY LTD PO BOX 8 KILSYTH VIC 3136 PH 03 9737 5300 FAX 03 9761 6455 www shamicheating com au ...

Страница 2: ...LED IN ACCORDANCE WITH AUSTRALIAN STANDARD AS 2918 AND THE APPROPRIATE REQUIREMENTS OF THE LOCAL BUILDING REGULATORY AUTHORITY WARNING BURN ONLY HARDWOOD WARNING DO NOT USE FLAMMABLE LIQUIDS SUCH AS PETROL KEROSENE OR ENGINE OIL TO START OR REKINDLE THE FIRE CAUTION MIXING OF APPLIANCE OR FLUE SYSTEM COMPONENTS FROM DIFFERENT SOURCES OR MODIFYING THE DIMENSIONAL SPECIFICATIONS OF COMPONENTS MAY RE...

Страница 3: ... or masonry fireplace connected to a chimney both of which shall be inspected for soundness and thoroughly cleaned before the heater is installed After removing the packaging slide the heater into the fireplace opening A flue system shall be connected to the heater providing free and effective discharge of combustion by products outside the building and any enclosed or confined space Arrow models ...

Страница 4: ...ntrol to desired level As well as keeping recommended firewood sizes in mind the way you load the fuel will affect the operating characteristics of your Arrow heater Always ensure adequate air is provided for combustion and to reduce creosote a smaller intense fire is preferable to a large smouldering one If a large log is placed across the width of the firebox more often than not the wood will sm...

Страница 5: ...t least 2 3 full set the air inlet control to high and let the heater operate in this manner for at least 90 minutes Note Ensure that the heater fan is switched to high during this procedure failure to do so may result in excessive deflection of the heater top panel or damage to the fan wiring Paint curing To prevent discolouration of the high temperature paint do not burn a large fire until the p...

Страница 6: ...sh being most effective If you experience heavy tar like deposits then inspect your fuel and review your operating methods Wet or green wood will cause heavy creosote deposits on the glass as well as the flue system and will severely restrict your heaters performance WARNING DO NOT OPERATE THE HEATER IF THE DOOR GLASS IS CRACKED Door glass seal Before lighting the first fire of the heating season ...

Страница 7: ...rest on the floor of the firebox 3 Lower the front of the baffle until it clears the support brackets remove it from the firebox The baffle plate should be removed and inspected annually and flaky deposits shaken or brushed off The most convenient time to maintain the baffle is when the flue is being cleaned Flue system Under normal conditions using dry hardwood and employing correct operating pro...

Страница 8: ...be over emphasized as it is critical to your heater s performance The relevant moisture content wetness of wood is indicated in the following table Moisture Content Fuel Suitability Below 10 Very dry Wood burns but less efficiently as some moisture is needed for ideal combustion 10 18 Ideal Wood burns efficiently and economically 18 25 Wood will burn but less efficiently Above 25 Wood too wet to b...

Страница 9: ...that sold you the heater 5 Advise them of the specific problem 6 Provide the details that your retailer requests to complete a Warranty Claim Form This must include the heater model serial number and installation compliance certificate if applicable in your State 7 Your retailer will forward your claim to Shamic Sheetmetal Aust Pty Ltd the manufacturer of the above heater brands 8 Shamic will cont...

Страница 10: ...f Building Codes Since building code requirements vary users should determine in advance whether there are any building code restrictions on the installation or use of the heater Shamic makes no representation of warranty regarding building code compliance and shall not be responsible for compliance therewith g Shamic will only accept claims under this warranty in strict accordance with the condit...

Отзывы: