21
12.3
SPILLAGE CHECK
A spillage check must be made before leaving the installed appliance with the
customer. Make this with all the ceramic coals in position.
12.3.1
Close all doors and windows in the room containing the
appliance.
12.3.2
Light the appliance and set the slide control to the maximum
burning position.
12.3.3
Leave the appliance on for five minutes.
12.3.4
Place the smoke match tube into the convection box at the right
hand side and immediately below the black top cross member. Angle it at
approximately 45° to the horizontal.
Insert the tube so that the neck of its flared end touches the inside surface
of the edge of the cross member (figure 36).
Keeping the neck of flared end in contact with the edge of the cross
member, slide the tube to the left until you feel it enter the notch in the edge of the cross
member. Make sure that the tube is pointed upwards at 45º to the horizontal.
The installation is satisfactory if the smoke is drawn into the appliance. If the smoke is not
drawn into the appliance, leave the appliance alight at the maximum setting for a further
ten minutes and then repeat the test. If the smoke is still not drawn into the appliance,
inspect the sealing to the fireplace surround. If the sealing is satisfactory but the appliance
is installed with the flue restrictor (see section 6.6), remove the restrictor, reseal the
appliance and retest. If smoke is still not drawn into the appliance
disconnect the appliance
and seek expert advice.
12.3.5
If the above test is satisfactory, open all internal connecting doors, hatches, etc. in
the room. Keep all doors and windows that open to the outside of the building closed.
Switch on any extractor fan installed in the same room as the appliance or a connecting
room. Open all doors and other openings between the fan and the appliance. Recheck for
spillage as above. If the smoke is drawn into the appliance, continue with the installation.
If the test is not satisfactory,
disconnect the appliance and advise the customer of the cause of
failure.
Fig. 36 Smoke Match Tube Position
Содержание Marseille BR622