User’s Manual – PGT
®
130.DT
Part No.: 7100.PGT130.DT
Page 9 / 21
V12/2020
Device settings
·
Measure voltage: 30V, 50V,
100V
·
Measure modes:
o
AND - Shoe and wrist measurement required
o
OR
- Shoe measurement
o
WRIST - Only wrist measurement required
o
SHOE - Only shoe measurement required
·
Internal buzzer:
ON
, OFF
·
Low limit shoe (100k
Ω
) and wrist (750k
Ω
)
ON
, OFF
·
Upper Limit Shoe
o
20 M
Ω
, 35M
Ω
, 70 M
Ω
,
100 M
Ω
·
Upper limit Wrist
o
35 M
Ω
, 100M
Ω
, 1000 M
Ω
(100V measure
voltage required)
·
Measurement without hands (shoe to shoe)
o
ON,
OFF
·
Relay pulse length:
1s
, 2s, 3s
·
Internal RFID reader:
ON
, OFF (OFF= external or no input device)
·
Enable/Disable configuration buttons:
ON
, OFF (Tempering protection)
Manual IP-Address Configuration
·
Log into the configuration page with your username and password.
·
Select
Configuration -> Network
·
Enter the desired IP-Address and associated Netmask carefully.
·
If required, a gateway address can be
·
defined.
·
Save the settings and reboot the
device with
Configuration ->
Reboot.
Recovery
If you've entered an incorrect IP-Address, the device is not accessible within the network any
more.
To rectify the faulty settings keep the right button pressed during start-up. Hereby the
manual settings are ignored and the device will start with network defaults.