background image

NOTE:  In line with its policy to continually improve its product, Wolf Range Company

reserves the right to change materials and specifications without notice.

This appliance is manufactured for commercial use only and is not intended for home use.

F-39079 (04-07)

Model IRB36

Gas Infrared Salamander Broiler

INSTALLATION REQUIREMENTS:
1.  A  gas  pressure  regulator  sized  for  this  unit  is  included.  

Natural Gas 5.0" W.C. Propane Gas 10.0" W.C.

2.  Gas line connecting to appliance must be ¾" diameter or 

larger. If flexible connectors are used, the inside diameter 
must be the same as the ¾" iron pipe.

3.  An  adequate  ventilation  system  is  required  for  commer-

cial  cooking  equipment.  Information  may  be  obtained  
by  writing  to  the  National  Fire  Protection Association,  
1 Batterymarch Park, Quincy, MA 02169, www.NFPA.org. 
When writing, refer to NFPA No. 96.

4.  These units are manufactured for installation in accordance 

with National Fuel Gas Code, ANSI-Z223.1/NFPA #54 (lat-
est edition). Copies may be obtained from The American 
Gas  Association,  Accredited  Standards  Committee  Z223 

 

Model 

 

 

 

Grid Rack 

Total 

Approx. Shp.

 

No. 

Width 

Depth 

Height 

(w x d) 

BTU/hr. 

Wt. (lbs./kg)

 

IRB36 

36" 

19" 

17½" 

27½" x 13" 

30,000 

180/81

@  400N.  Capital  St.  NW,  Washington,  DC  20001,  or  the 
Secretary Standards Council, NFPA, 1 Batterymarch Park, 
Quincy, MA 02169-7471.

 

 

NOTE: In the Commonwealth of Massachusetts

 

All  gas  appliances  vented  through  a  ventilation  hood  or 
exhaust system equipped with a damper or with a power 
means of exhaust shall comply with 248 CMR. 

5.  Clearances:
 

 

Combustible 

Non-Combustible

 

Rear 

0" 

0"

 

Sides 

2" 

0"

 

Bottom 

10" 

4"

Отзывы: