background image

Installation Considerations

4

Before You Start

Proper installation is the responsibility of the installer.

Product failure due to improper installation is not

covered under the Wolf warranty. Refer to the down-

draft ventilation use & care guide for warranty details,

or visit our website, wolfappliance.com.

Check with local utilities for electrical codes that apply

in your area. Local codes vary. Installation, electrical

connections and grounding must comply with applica-

ble codes. In the absence of local codes, this appli-

ance should be installed in accordance with National

Electrical Code ANSI/NFPA 70-1990 or latest edition.

This appliance must be properly grounded. Refer to

electrical requirements on page 8.

Make sure you have the tools and materials necessary

for proper installation.

Any required service must be performed by a Wolf

authorized service center.

Installation Considerations

Wolf downdraft systems can be used with all Wolf induc-

tion, electric and gas cooktops, except unframed models.

Wolf downdraft systems cannot be used with the steamer

or fryer module and are not recommended for use with the

electric grill module. A downdraft can also be used with

sealed burner rangetop models SRT304 and SRT366.

An accessory trim kit is necessary for this installation.

Contact your authorized Wolf dealer for details.

Wolf downdraft ventilation systems can be mounted in an

island, peninsula or standard wall location.

Wolf downdraft model DD30 will fit most 30" (762) wide

cabinets, model DD36 will fit most 36" (914) wide cabinets

and model DD45 will fit most 45

1

/

2

" (1156) wide cabinets.

It is recommended that oversized cabinets be used for

easier installation. The cabinet back may need to be

removed.

Содержание DD36I

Страница 1: ...Downdraft Ventilation INSTALLATION GUIDE ...

Страница 2: ...f instructions are not followed WARNING states a hazard that may cause serious injury or death if precautions are not followed Contents Wolf Downdraft Ventilation 3 Installation Considerations 4 Downdraft Specifications 5 Downdraft Installation 9 Service Information 15 Features and specifications are subject to change at any time without notice Visit wolfappliance com specs for the most up to date...

Страница 3: ...nce com This appliance must be installed in accordance with National Electrical Codes as well as all state municipal and local codes The correct voltage frequency and amperage must be supplied to the appliance from a dedi cated grounded circuit which is protected by a properly sized circuit breaker or time delay fuse The proper voltage frequency and amperage ratings are listed on the product ratin...

Страница 4: ...ials necessary for proper installation Any required service must be performed by a Wolf authorized service center Installation Considerations Wolf downdraft systems can be used with all Wolf induc tion electric and gas cooktops except unframed models Wolf downdraft systems cannot be used with the steamer or fryer module and are not recommended for use with the electric grill module A downdraft can...

Страница 5: ...mensions MODELS DD30I AND DD30R 23 8 60 30 762 91 16 230 261 4 667 11 2 38 DEPTH OF CHIMNEY 36 914 321 4 819 23 8 60 91 16 230 11 2 38 DEPTH OF CHIMNEY MODELS DD36I AND DD36R MODELS DD45I AND DD45R 451 2 1156 411 4 1048 23 8 60 91 16 230 11 2 38 DEPTH OF CHIMNEY ...

Страница 6: ...stem and a Wolf cooktop you must allow for a minimum 251 8 638 flat counter space from front to back A countertop with a raised lip or backsplash may not allow enough space for proper installation 23 8 60 of flat countertop is required behind the cooktop and 13 4 44 is necessary between the back edge of the cooktop and inside of cabinet back Refer to the illustrations for specifications for a down...

Страница 7: ...top is to be installed flush with cabinet face Installation Specifications For installation of a downdraft with a sealed burner rangetop refer to the sealed burner rangetop installation guide for rangetop dimensions rough opening and cabinet requirements Refer to the illustrations for specifications for a downdraft model DD30 or DD36 installed with a Wolf sealed burner rangetop model SRT304 or SRT...

Страница 8: ...de cabinet or model DD45 in a 451 2 1156 wide cabinet the electrical outlet cannot be located on the back wall of the cabinet The outlet can be placed in an adjacent cabinet within reach of the power cord An access hole for the power cord must be drilled in the cabinet wall IMPORTANT NOTE A ground fault circuit interrupter GFCI is not recommended and may cause interruption of operation You must fo...

Страница 9: ...ges of the countertop INSTALL THE DOWNDRAFT Set the downdraft into the opening Extend the leveling brackets to the floor of the cabinet so the downdraft sits straight Note that the leveling brackets can be removed and reattached in a different position The flange of the leveling bracket may have to face inward in tight cabinet installations Refer to the illustration below Secure the downdraft to t...

Страница 10: ...o the illustration placed on the front of the downdraft for the correct orientation of the RJ45 connector during installation into the downdraft assembly Control Module IMPORTANT NOTE The downdraft must be used with a Wolf approved control module and top cover The 23 8 60 x 65 8 168 remote mounted control module and stainless steel top cover are included with the downdraft Also included are mounti...

Страница 11: ...HVAC professional for specific installation and ducting applications Downdraft models with an internal blower have a 31 4 83 x 10 254 duct and remote blower models have a 31 4 83 x 14 356 duct Each can be transitioned to 8 203 or 10 254 round ductwork All downdrafts have an adjustable discharge For best performance 10 254 round ductwork is recom mended The downdraft will operate most efficiently w...

Страница 12: ...ctwork IMPORTANT NOTE Use duct tape to seal the connection between the blower outlet and ductwork Support the weight of the ductwork as necessary to ensure sealed joints Adjustable Discharge Wolf downdraft systems have an adjustable discharge that will allow you to negotiate ducting around floor joists and other obstacles Three different discharge locations are available with side to side adjustme...

Страница 13: ...l screws through the bottom flange to secure the bottom of the blower CLAMP CHANNEL NUT BLOWER COVER PLATE MOTOR PLUG SCREW Left or right side discharge Blower Discharge Adjustment DOWN DISCHARGE ADJUSTMENT Adjusting the down discharge left or right will keep the blower discharge in the down position but allows some side to side adjustment Follow these steps if the position of the blower discharge...

Страница 14: ...y not exceed a 6 0 amp rating Run 2 wire plus ground power cable from the remote blower to the electrical box on the remote blower adapter plate Connect the downdraft wiring to the power cable from the remote blower Wire black to black white to white and green to green or bare wire Refer to the illustration below Replace the electrical box cover Plug the downdraft power cord into the outlet Wiring...

Страница 15: ... your gas range by calling a Wolf authorized service center To obtain the name and number of a Wolf authorized service center check the contact support section of our website wolfappliance com or call Wolf customer service at 800 332 9513 When calling for service you will need the model and serial numbers of the downdraft This information is found on the product rating plate located above the blow...

Страница 16: ...WOLF APPLIANCE INC P O BOX 44848 MADISON WI 53744 WOLFAPPLIANCE COM 800 332 9513 808256 REV D 1 2010 ...

Отзывы: