Downdraft Installation

11

wolfappliance.com/specs

Blower Considerations

Downdraft models DD30I, DD36I and DD45I include a 500

CFM internal blower. In-line and remote blower assemblies

are available for models DD30R, DD36R and DD45R

through your authorized Wolf dealer. For local dealer infor-

mation, visit the showroom locator section of our website,

wolfappliance.com.

Blower options vary with the cooking surface, the volume

of air that needs to be moved and the length of the duct

run. A straight, short duct run with a limited number of

elbows and transitions will allow the downdraft to perform

most efficiently. A remote-mounted blower will minimize

the amount of blower noise, but will not eliminate the

noise completely.

Refer to ventilation recommendations in the Wolf design

guide found on our website, wolfappliance.com.

Ducting Considerations

IMPORTANT NOTE:

Consult a qualified HVAC professional

for specific installation and ducting applications.

Downdraft models with an internal blower have a

3

1

/

4

" (83) x 10" (254) duct and remote blower models

have a 3

1

/

4

" (83) x 14" (356) duct. Each can be transitioned

to 8" (203) or 10" (254) round ductwork. All downdrafts

have an adjustable discharge.

For best performance, 10" (254) round ductwork is recom-

mended. The downdraft will operate most efficiently when

the ductwork does not exceed 40' (12 m) in length.

Choose the ducting option that allows the shortest length

of ductwork and a minimum number of elbows and transi-

tions. Check the location of floor joists, wall studs, electri-

cal wiring and plumbing for possible interference with the

ductwork. Refer to the illustrations below for ducting

options.

12"

MIN

TO

GROUND

WALL CAP

INTERNAL BLOWER

INSTALLATION THROUGH WALL

R

Internal blower ducting options.

12"

MIN

TO

GROUND

INTERNAL BLOWER

INSTALLATION THROUGH WALL

12"

MIN

TO

GROUND

10"

ROUND

REMOTE BLOWER

INSTALLATION THROUGH WALL

REMOTE
BLOWER

REMOTE BLOWER

ROOF MOUNT INSTALLATION

1

REMOTE
BLOWER

10"

ROUND

Remote blower ducting options.

Содержание DD36I

Страница 1: ...Downdraft Ventilation INSTALLATION GUIDE ...

Страница 2: ...f instructions are not followed WARNING states a hazard that may cause serious injury or death if precautions are not followed Contents Wolf Downdraft Ventilation 3 Installation Considerations 4 Downdraft Specifications 5 Downdraft Installation 9 Service Information 15 Features and specifications are subject to change at any time without notice Visit wolfappliance com specs for the most up to date...

Страница 3: ...nce com This appliance must be installed in accordance with National Electrical Codes as well as all state municipal and local codes The correct voltage frequency and amperage must be supplied to the appliance from a dedi cated grounded circuit which is protected by a properly sized circuit breaker or time delay fuse The proper voltage frequency and amperage ratings are listed on the product ratin...

Страница 4: ...ials necessary for proper installation Any required service must be performed by a Wolf authorized service center Installation Considerations Wolf downdraft systems can be used with all Wolf induc tion electric and gas cooktops except unframed models Wolf downdraft systems cannot be used with the steamer or fryer module and are not recommended for use with the electric grill module A downdraft can...

Страница 5: ...mensions MODELS DD30I AND DD30R 23 8 60 30 762 91 16 230 261 4 667 11 2 38 DEPTH OF CHIMNEY 36 914 321 4 819 23 8 60 91 16 230 11 2 38 DEPTH OF CHIMNEY MODELS DD36I AND DD36R MODELS DD45I AND DD45R 451 2 1156 411 4 1048 23 8 60 91 16 230 11 2 38 DEPTH OF CHIMNEY ...

Страница 6: ...stem and a Wolf cooktop you must allow for a minimum 251 8 638 flat counter space from front to back A countertop with a raised lip or backsplash may not allow enough space for proper installation 23 8 60 of flat countertop is required behind the cooktop and 13 4 44 is necessary between the back edge of the cooktop and inside of cabinet back Refer to the illustrations for specifications for a down...

Страница 7: ...top is to be installed flush with cabinet face Installation Specifications For installation of a downdraft with a sealed burner rangetop refer to the sealed burner rangetop installation guide for rangetop dimensions rough opening and cabinet requirements Refer to the illustrations for specifications for a downdraft model DD30 or DD36 installed with a Wolf sealed burner rangetop model SRT304 or SRT...

Страница 8: ...de cabinet or model DD45 in a 451 2 1156 wide cabinet the electrical outlet cannot be located on the back wall of the cabinet The outlet can be placed in an adjacent cabinet within reach of the power cord An access hole for the power cord must be drilled in the cabinet wall IMPORTANT NOTE A ground fault circuit interrupter GFCI is not recommended and may cause interruption of operation You must fo...

Страница 9: ...ges of the countertop INSTALL THE DOWNDRAFT Set the downdraft into the opening Extend the leveling brackets to the floor of the cabinet so the downdraft sits straight Note that the leveling brackets can be removed and reattached in a different position The flange of the leveling bracket may have to face inward in tight cabinet installations Refer to the illustration below Secure the downdraft to t...

Страница 10: ...o the illustration placed on the front of the downdraft for the correct orientation of the RJ45 connector during installation into the downdraft assembly Control Module IMPORTANT NOTE The downdraft must be used with a Wolf approved control module and top cover The 23 8 60 x 65 8 168 remote mounted control module and stainless steel top cover are included with the downdraft Also included are mounti...

Страница 11: ...HVAC professional for specific installation and ducting applications Downdraft models with an internal blower have a 31 4 83 x 10 254 duct and remote blower models have a 31 4 83 x 14 356 duct Each can be transitioned to 8 203 or 10 254 round ductwork All downdrafts have an adjustable discharge For best performance 10 254 round ductwork is recom mended The downdraft will operate most efficiently w...

Страница 12: ...ctwork IMPORTANT NOTE Use duct tape to seal the connection between the blower outlet and ductwork Support the weight of the ductwork as necessary to ensure sealed joints Adjustable Discharge Wolf downdraft systems have an adjustable discharge that will allow you to negotiate ducting around floor joists and other obstacles Three different discharge locations are available with side to side adjustme...

Страница 13: ...l screws through the bottom flange to secure the bottom of the blower CLAMP CHANNEL NUT BLOWER COVER PLATE MOTOR PLUG SCREW Left or right side discharge Blower Discharge Adjustment DOWN DISCHARGE ADJUSTMENT Adjusting the down discharge left or right will keep the blower discharge in the down position but allows some side to side adjustment Follow these steps if the position of the blower discharge...

Страница 14: ...y not exceed a 6 0 amp rating Run 2 wire plus ground power cable from the remote blower to the electrical box on the remote blower adapter plate Connect the downdraft wiring to the power cable from the remote blower Wire black to black white to white and green to green or bare wire Refer to the illustration below Replace the electrical box cover Plug the downdraft power cord into the outlet Wiring...

Страница 15: ... your gas range by calling a Wolf authorized service center To obtain the name and number of a Wolf authorized service center check the contact support section of our website wolfappliance com or call Wolf customer service at 800 332 9513 When calling for service you will need the model and serial numbers of the downdraft This information is found on the product rating plate located above the blow...

Страница 16: ...WOLF APPLIANCE INC P O BOX 44848 MADISON WI 53744 WOLFAPPLIANCE COM 800 332 9513 808256 REV D 1 2010 ...

Отзывы: