Access & Removal
CT Hoods and DD Ventilation
4-10
I
NTERNAL
B
LOWER
R
EMOVAL
(
CONTINUED
)
Remove the wing-nuts on either side of the blower
9.
housing. (See Figure 24)
While supporting the blower, remove the screws
10.
(Figure 25). Once the screws are removed the blower
can be lowered out of the hood.
NOTE:
You will need to rotate the blower assembly
slightly within the hood to attain the correct
orientation for removal.
NOTE:
Do not lose the tubular screw spacers that
are inside of the rubber mounts. These spacers
prevent the possibility of crushing the rubber mount
during reinstallation.
Figure 4-24 Blower Mounting Wing-nuts
Figure 4-25 Blower Mounting Screws
C
ONTROL
B
OARD
R
EMOVAL
Disconnect electrical supply. (See
1.
WARNING
above)
Slide the bottom section of chimney fl ue up to gain
2.
access to the controls. (See Figure 20)
Remove the Control Board housing cover and unplug
3.
electrical connectors.
NOTE:
Mark wire connectors as you remove them to
insure proper connection on replacement board.
TO AVOID ELECTRIC SHOCK, POWER TO THE
VENTILATION UNIT MUST BE DISCONNECTED
WHENEVER PERFORMING THE FOLLOWING
REPAIRS.
ALWAYS WEAR GLOVES WHEN HANDLING SHEET
METAL DUE TO THE POSSIBILITY OF SHARP
EDGES.
Содержание CT
Страница 2: ......
Страница 3: ...1 1 General Information CT Hoods and DD Ventilation SECTION 1 GENERAL INFORMATION ...
Страница 8: ...1 6 General Information CT Hoods and DD Ventilation NOTES ...
Страница 9: ...2 1 Installation Information CT Hoods and DD Ventilation SECTION 2 INSTALLATION INFORMATION ...
Страница 35: ...Controls Operation CT Hoods and DD Ventilation 3 1 SECTION 3 CONTROLS OPERATION ...
Страница 39: ...Access Removal CT Hoods and DD Ventilation 4 1 SECTION 4 COMPONENT ACCESS REMOVAL ...
Страница 54: ...Access Removal CT Hoods and DD Ventilation 4 16 NOTES ...
Страница 55: ...5 1 Troubleshooting CT Hoods and DD Ventilation SECTION 5 TROUBLESHOOTING ...
Страница 62: ...5 8 Troubleshooting CT Hoods and DD Ventilation NOTES ...
Страница 63: ...6 1 Technical Data CT Hoods and DD Ventilation SECTION 6 TECHNICAL DATA ...
Страница 66: ...6 4 Technical Data CT Hoods and DD Ventilation NOTES ...
Страница 67: ...Wiring Schematics CT Hoods and DD Ventilation 7 1 SECTION 7 WIRING DIAGRAMS SCHEMATICS ...
Страница 68: ...Wiring Schematics CT Hoods and DD Ventilation 7 2 MODEL CTWH30 WIRING DIAGRAM ...
Страница 69: ...Wiring Schematics CT Hoods and DD Ventilation 7 3 MODEL CTWH36 WIRING DIAGRAM ...
Страница 70: ...Wiring Schematics CT Hoods and DD Ventilation 7 4 MODEL IH4227 WIRING DIAGRAM ...
Страница 72: ...Wiring Schematics CT Hoods and DD Ventilation 7 6 MODEL DD30 DD36 SCHEMATIC ...
Страница 76: ...Wiring Schematics CT Hoods and DD Ventilation 7 10 MODEL DD30 DD36 CONTROL SCHEMATIC ...
Страница 77: ...Wiring Schematics CT Hoods and DD Ventilation 7 11 MODEL DD POWER SUPPLY WIRING ...
Страница 79: ...Wiring Schematics CT Hoods and DD Ventilation 7 13 BLOWER WIRING DIAGRAM SCHEMATIC 450 600 900INT ...
Страница 80: ...Wiring Schematics CT Hoods and DD Ventilation 7 14 BLOWER SCHEMATIC 600 900EXT ...
Страница 81: ...Wiring Schematics CT Hoods and DD Ventilation 7 15 BLOWER SCHEMATIC 1200EXT ...
Страница 82: ...Wiring Schematics CT Hoods and DD Ventilation 7 16 BLOWER SCHEMATIC 1500EXT ...
Страница 83: ...8 1 Parts Exploded CT Hoods and DD Ventilation SECTION 8 PARTS LISTS EXPLODED VIEWS ...
Страница 98: ...8 16 Parts Exploded CT Hoods and DD Ventilation NOTES ...