2-21
Installation Information
CT Hoods and DD Ventilation
D
OWNDRAFT
D
IMENSIONS
NOTE:
Wolf downdraft ventilation systems are recommended for use with Wolf framed electric, gas, induction and
multi-function cooktops. They cannot be used with unframed electric cooktops and are not recommended for use with
the electric grill, steamer and fryer modules. A Pro ventilation hood must be used with Wolf dual fuel ranges, gas
ranges and rangetops.
Wolf downdraft ventilation systems are available in 30” (762), 36” (914) and 45-1/2”(1156) widths. The downdraft
should be at least as wide as the cooktop. Models DD30I, DD36I and DD45I include a 500CFM internal blower. Mod-
els DD30R, DD36R and DD45R are shipped without a blower assembly.
TO REDUCE THE RISK OF FIRE AND ELECTRIC SHOCK, THIS VENTILATION HOOD SHOULD ONLY BE
INSTALLED WITH BLOWERS MANUFACTURED BY WOLF APPLIANCE INC. AND SPECIFIED FOR USE WITH
THESE VENTILATION MODELS.
Figure 2-
41
Models DD30I & DD30R
Figure 2-42 Models DD36I & DD36R
Figure 2-43 Models DD45I & DD45R
M O D E L S D D 3 0 I A N D D D 3 0 R
O
)
2
6
7
(
"
0
3
h
t
d
i
W
l
l
a
r
e
v
Width of Chimney
26
1
/
4
" (667)
Overall Height (above countertop) 9
1
/
16
" (230)
2
h
t
p
e
D
l
l
a
r
e
v
O
3
/
8
" (60)
Depth of Chimney
1
1
/
2
" (38)
M O D E L S D D 3 6 I A N D D D 3 6 R
)
4
1
9
(
"
6
3
h
t
d
i
W
l
l
a
r
e
v
O
Width of Chimney
32
1
/
4
" (819)
Overall Height (above counter top) 9
1
/
16
" (230)
Overall Depth
2
3
/
8
" (60)
Depth of Chimney
1
1
/
2
" (38)
M O D E L S D D 4 5 I A N D D D 4 5 R
Overall Width
45
1
/
2
" (1156)
Width of Chimney
41
1
/
4
" (1048)
Overall Height (above countertop) 9
1
/
16
" (230)
Overall Depth
2
3
/
8
" (60)
Depth of Chimney
1
1
/
2
" (38)
Dimensions may vary to +–
1
/
8
" (3).
Dimensions may vary to +–
1
/
8
" (3).
Dimensions may vary to +–
1
/
8
" (3).
Содержание CT
Страница 2: ......
Страница 3: ...1 1 General Information CT Hoods and DD Ventilation SECTION 1 GENERAL INFORMATION ...
Страница 8: ...1 6 General Information CT Hoods and DD Ventilation NOTES ...
Страница 9: ...2 1 Installation Information CT Hoods and DD Ventilation SECTION 2 INSTALLATION INFORMATION ...
Страница 35: ...Controls Operation CT Hoods and DD Ventilation 3 1 SECTION 3 CONTROLS OPERATION ...
Страница 39: ...Access Removal CT Hoods and DD Ventilation 4 1 SECTION 4 COMPONENT ACCESS REMOVAL ...
Страница 54: ...Access Removal CT Hoods and DD Ventilation 4 16 NOTES ...
Страница 55: ...5 1 Troubleshooting CT Hoods and DD Ventilation SECTION 5 TROUBLESHOOTING ...
Страница 62: ...5 8 Troubleshooting CT Hoods and DD Ventilation NOTES ...
Страница 63: ...6 1 Technical Data CT Hoods and DD Ventilation SECTION 6 TECHNICAL DATA ...
Страница 66: ...6 4 Technical Data CT Hoods and DD Ventilation NOTES ...
Страница 67: ...Wiring Schematics CT Hoods and DD Ventilation 7 1 SECTION 7 WIRING DIAGRAMS SCHEMATICS ...
Страница 68: ...Wiring Schematics CT Hoods and DD Ventilation 7 2 MODEL CTWH30 WIRING DIAGRAM ...
Страница 69: ...Wiring Schematics CT Hoods and DD Ventilation 7 3 MODEL CTWH36 WIRING DIAGRAM ...
Страница 70: ...Wiring Schematics CT Hoods and DD Ventilation 7 4 MODEL IH4227 WIRING DIAGRAM ...
Страница 72: ...Wiring Schematics CT Hoods and DD Ventilation 7 6 MODEL DD30 DD36 SCHEMATIC ...
Страница 76: ...Wiring Schematics CT Hoods and DD Ventilation 7 10 MODEL DD30 DD36 CONTROL SCHEMATIC ...
Страница 77: ...Wiring Schematics CT Hoods and DD Ventilation 7 11 MODEL DD POWER SUPPLY WIRING ...
Страница 79: ...Wiring Schematics CT Hoods and DD Ventilation 7 13 BLOWER WIRING DIAGRAM SCHEMATIC 450 600 900INT ...
Страница 80: ...Wiring Schematics CT Hoods and DD Ventilation 7 14 BLOWER SCHEMATIC 600 900EXT ...
Страница 81: ...Wiring Schematics CT Hoods and DD Ventilation 7 15 BLOWER SCHEMATIC 1200EXT ...
Страница 82: ...Wiring Schematics CT Hoods and DD Ventilation 7 16 BLOWER SCHEMATIC 1500EXT ...
Страница 83: ...8 1 Parts Exploded CT Hoods and DD Ventilation SECTION 8 PARTS LISTS EXPLODED VIEWS ...
Страница 98: ...8 16 Parts Exploded CT Hoods and DD Ventilation NOTES ...