No Power supply / Power supply removed / Power line outage
If the AC power supply was removed or in case of a detected electricity / power outage, after
min. 5 seconds the device will be disconnecting all interfaces, file systems, micro-SD card and
afterall will be shutdown. This extra operation time is possible due to the internal supercapacitor
–
which provides safe backup power for short time outages.
During the shutdown process only the
ON
LED will be lighting by
green
, but the
PWR
LED will
be
blank
. When the shutdown process has been finished,
all LEDs will be inactive.
Replug power supply / Stabilizing the power line
In case of providing the AC power source (replugging the power supply) or stabilizing the outage
of the power source, the device will getting enough power again and automatically starting.
During these the
PWR
and
ON
LEDs will be active (ligthing by
green
).
Because the supercapacitor was used previously, it needs to be charged - therefore the
SUPERCAPACITOR CHARGE
led will be also active during the charging process (ligthing by
yellow
).