background image

IR Intelligent Speed Dome Camera User Manual 

 

- 9 - 

2

Stay time setting for preset position when auto cruising 

It can set stay time for preset position as 4 /8 /10 /15 /20 Seconds when the IR dome camera 

auto  cruising.  Operation  method  by  controlling  keyboard,  DVR  to  implement  the  command  “set 

No.75 preset position” the stay time is 4 sec;“set No.76 preset position”

the stay time is 8 sec;Stay 

time setting command for auto cruising reference as below table; 

Stay time 

Set commands 

Stay time 

Set commands 

4s 

Call 

NO.

75 preset 

8s 

Call 

NO.

76 preset 

10s 

Call 

NO.

77 preset 

15s 

Call 

NO.

78 preset 

20s 

Call 

NO.

79 preset 

 

 

Example: using a type of controlling keyboard to set the stay time as 8 sec 

a

Enter“76” 

b

Press “SHOT” key; 

c

Press “ACK” key; 

4 cruising routes of corresponding preset position number for cruise route and the relation table of 

calling or delete command 

Example;Use a keyboard to remove the preset position of the third automatically cruise routes.   

a

Enter“73” 

b

Press “SHOT” key; 

c

Press “ACK” key; 

Corresponding preset position number for cruise route and the relation table of calling command 

Cruise route 

Call command 

Presets in cruise route 

NO.1 

Call 

NO.

71 preset 

1—16 presets 

NO.2 

Call 

NO.

72 preset 

17—32 presets 

NO.3 

Call 

NO.

73 preset 

33—48 presets 

NO.4 

Call 

NO.

74 preset 

240—255 presets 

 

5.3 limit positions on left and right(A to B) 

360 degree scan

setting and remove the setup of 

scanning speed. 

The  IR  dome  uses  the  conductive  ring  and  photo  electricity  to  limit  position

it  can  get 

through the controlling keyboard and DVR to set the left and right rotation position of the dome. 

and automatically scan between the limit position of setting. 

1

A

B scan setting. 

By  controlling  keyboard  or  DVR  to  implement  the  command  “set  No.91  preset  position” 

after  moved  the  dome  to  the  right  for  the  required  position 

Implementing  the  command  “set 

No.92 preset position” after make the dome rotating to the left to the position of left limit position, 

left  and  right  limit  position  is  setting  done.  Then  calling  No.93  preset  position,  the  dome  just 

running between these two points only. 

Example: use a type of controlling keyboard to set limit position on left and right 

a

Press  the  key  “set  preset”,  Then  make  the  camera  moved  to  the  need  position  by  shaking 

joystick. 

b

Enter“91”; 

Содержание ON-AP6RK-33X-2M

Страница 1: ...IR Intelligent Speed Dome Camera User Manual...

Страница 2: ...installation Don t touch the dome cover directly by hand When connecting the power source please follow all electric safety standards and only use the power supply designed for this device Keep the v...

Страница 3: ...etting and remove the setup of scanning speed 9 5 4 Factory Default 10 6 System OSD menu setup for models with OSD menu 11 6 1 Self Test Display 11 6 2 Main Menu 11 6 3 Syetem Information 12 6 4 Syste...

Страница 4: ...ble that are damaged under normal use by judge of us at no additional charge Free services and repairs will not be covered under the following conditions 1 Unauthorized repair or disassembly of the pr...

Страница 5: ...d make the irradiation Angle difference from the viewing Angle of current camera for the IR light producing periodic rest reduce the infrared lamp panel working current effectively control components...

Страница 6: ...oard etc Preset 255 presets Patrol 4 groups 16 presets per group stay time for each preset positions 4 8 10 15 20 seconds adjustable Patter 4 groups 3 mins per pattern Scan one group frame scan one gr...

Страница 7: ...d PTZ and camera lens control of dome camera This product designed the dial switch located on the sphere given the set of convenient and stability there is a piece of gusset plate under the ball cover...

Страница 8: ...38 10101100 53 10010000 9 00011000 24 11100100 39 01101100 54 01010000 10 10011000 25 00010100 40 11101100 55 11010000 11 01011000 26 10010100 41 00011100 56 00110000 12 11011000 27 01010100 42 100111...

Страница 9: ...to the angle in demand by pressing the key zoom b Enter 1 key c Press SHOT key d press and hold the smart key of the joystick e Press ON key 2 Call preset position Refer to the calling preset functio...

Страница 10: ...r cruise route and the relation table of calling command Cruise route Call command Presets in cruise route NO 1 Call NO 71 preset 1 16 presets NO 2 Call NO 72 preset 17 32 presets NO 3 Call NO 73 pres...

Страница 11: ...hen horizontal rotation speed of auto scanning operation method by controlling keyboard DVR to implement set No 65 preset position The scanning rotation speed is 3 sec set No 69 preset position the sc...

Страница 12: ...em Information System Setup Function Setup Display Setup Camera Menu Setup Factory Default Exit System Information Version V5 0 4 Address 01 Protocol Pelco D Self test OK System Setup motion flip on S...

Страница 13: ...1 version V5 0 4 2 address 01 3 protocol Pelco D 4 baud rate 2400 5 self test OK 6 back 6 4 System Setup Users can setup the speed dome function by this menu Move the cursor to system setup press righ...

Страница 14: ...5 Return 6 5 2 Idle Func Through Idel func you can set the PTZ camera Idle task and Idle waiting time when the PTZ mil in the setting f time without any operation the PTZ camera will perform to autom...

Страница 15: ...Trace func 1 Trace NO 01 2 Setting trace 3 Running trace 4 Clearing trace 5 Return 6 6 Display Information Through the Display information you can open and close the system time system position setti...

Страница 16: ...Intelligent Speed Dome Camera User Manual 15 6 8 Restore The Factory Value Chose Restore the factory value you can drop all of the PTZ camera s parameter such as 6 9 EXIT Chose exit to exit the PTZ me...

Страница 17: ...rd the third path call83 To record the fourth path call84 end of the recording track call85 Start the first track call86 Start the second track call87 Start the third track call88 Start the fourth tra...

Страница 18: ...n and external force factors it can be called the NO 96 preset postion to make a factory default 6 In order to control the infrared light calorific value effectively and ordinary infrared machine flas...

Страница 19: ...offer free repair but it will pay for the material cost when include any of below situation 1 It is damaged due to not follow the manual to operate 2 It is damaged due to lightning fire disaster and o...

Страница 20: ...rod or other measures 5 Lightning protection of outdoor installation and wiring and grounding design must be combined with the building lightning protection requirements into consideration as well as...

Страница 21: ...Eliminate Power shortage to the power supply Change Image is unstable Video cable is disturbed Eliminate Power shortage to the camera power supply Change the better power supply and best to put it nea...

Отзывы: