Original operation manual
2K GEL UNIT
19
2KGel_14025_25015_BAoDB_en_1701 • rs
Machine description
3.4 Compressed air connection
The connection of the compressed air line provided by the owner occurs at the
compressed air connection.
The compressed air supply for the entire machine is opened or interrupted with
the compressed air shut-off valve. Separate compressed air regulators are
present for the proportioning pump and flush pump. The existing pressure can
be read on the pressure gauges.
The
2K GEL UNIT
without a flush
pump is factory-equipped with a
compressed air regulator.
Fig. 6: Compressed air regulator
1
2
3
5
4
The
2K GEL UNIT
with a flush pump
is factory-equipped with an air
supply.
Fig. 7: Air supply
8
7
6
4
2
3
1
5
No. Designation
1
Pressure display for proportioning pump
2
Compressed air shut-off valve
3
Compressed air connection for the compressed air supply provided by
the owner
4
Compressed air regulator for proportioning pump
5
Compressed air connection for proportioning pump
6
Compressed air regulator for flush pump
7
Compressed air connection for flush pump
8
Pressure display for flush pump