EGO - STAR AIR version
Example of Perameters Chart in the Service Manual
Release Software
0503
0504
Revolution and flow parameters
Values
Values
Unit
Air flow in load wood phase
230
230
lpm
Minimum value of revolutions of the smoke fan in load wood phase
1900
1900
rpm
Air flow in fire on phase
180
180
lpm
Minimum value of revolutions of the smoke fan in fire on phase
1500
1500
rpm
Air flow in power 1
150
150
lpm
Minimum value of revolutions of the smoke fan in power 1
1300
1300
rpm
Air flow in power 2
155
155
lpm
Minimum value of revolutions of the smoke fan in power 2
1450
1450
rpm
Air flow in power 3
160
160
lpm
Minimum value of revolutions of the smoke fan in power 3
1600
1600
rpm
Air flow in power 4
165
165
lpm
Minimum value of revolutions of the smoke fan in power 4
1750
1750
rpm
Air flow in power 5
170
170
lpm
Minimum value of revolutions of the smoke fan in power 5
1900
1900
rpm
Air flow during thermal shutdown
150
150
lpm
Minimum value of revolutions during shutdown
2500
2500
rpm
Air flow during grate cleaning
350
350
lpm
Minimum value of revolutions of smoke fan during grate cleaning
2500
2500
rpm
Air flow during pre-lighting phase.
150
150
lpm
Minimum value of revolutions during pre-lighting
2500
2500
rpm
Minimum revolutions to detect a flow
500
500
rpm
Minimum operating flow
120
90
lpm
Rev/flow ratio to detect anomalies
20
27
Smoke temperature parameters
Unit
Minimum smoke temperature to consider the stove on
50
50
°
C
Maximum smoke temperature to consider the stove off
45
45
°
C
Temperature increase when lighting flame LW when hot
5
5
°
C
Minimum smoke temperature to start up the exchanger.
60
60
°
C
Smoke temperature to reduce the exchanger to minimum in ST.
100
100
°
C
Maximum smoke temperature to shut down the exchanger.
55
55
°
C
Pre-alarm threshold for smoke temperature
180
180
°
C
Alarm threshold for smoke temperature
200
200
°
C
Hysteresis for smoke temperature alarm thresholds
5
5
°
C