Technical specifications
INTORQ | BA 14.0214 | 09/2017
18
3.3
Rated data (design data)
Abb. 2
Operating/switching times of the spring-applied brakes
1)
Minimum brake torque with run-in friction components at
n=100 r/min
2)
Typical values
3)
Measured with induced voltage limitation of -800 V DC
4)
Max. speed according to EC-type examination certificate (for higher speeds, consultation with the manu-
facturer is required)
Disengagement time
The disengagement time is not influenced by DC or AC switching operations.
t
1
Engagement time
t
11
Reaction delay of engagement
t
2
Disengagement time (up to M = 0.1 M
dyn
)
t
12
Rise time of the braking torque
M
dyn
Braking torque at a constant speed of rotation
U Voltage
Type
Rated torque
1)
Max. perm.
Switching energy
Transitional operat-
ing frequency
Switching times [ms]
at s
LN
and 0.7 I
N
2)
Max. speed
4)
M
K
Q
E
S
hue
Engaging
DC side
3)
Disengaging
[NM]
[J]
[1/h]
t
11
t
12
t
1
t
2
n
max
[rpm]
BFK464-18
R
2x280
60000
20
33 100 133
150
900
BFK464-20
R
2x450
80000
19
27 138 165
180
900
Tab. 3:
Switching energy - operating frequency - switching times