Gearless Lift Machine
WSG-18 and WLG-18
Operating Instructions
Seite/page
11
Datum/date
14.02.2006
Stand/version
0.17
Änderungen vorbehalten!
Subject to changes without notice!
MADE BY
SAD GmbH
A MEMBER OF WITTUR
Motor connection diagram
terminal strip for
brake connection
running capacitor
for fan
motor terminals
terminal strip for fan and
winding protection con-
nections
M
3~
U1
V1
W1
PE
T1
T3
T2
T4
S1
S3
S2
S4
(Z)
L
N
υ
υ
υ
υ
υ
υ
υ
Terminal box
screwed cable entry
1 x tapped hole Pg 36
1 x tapped hole Pg 29
PTC-thermistor
T
3 x STM-150.ES... (150°C)
- integrated in the motor windings
- for motor protection
Thermostatic switch
S1
3 x S01.130.05.... (130°C)
(250 V AC / 2,5 A / cos
ϕ
= 1)
- integrated in the motor windings
- pre-warning overtemperature
M
Fan
F
D2E 133-AM47-A5
230 V / 50/60 Hz / 0,84/0,88 A
Thermostatic switch
S4
1 x S01.60.05.... (60°C)
(250 V AC / 2,5 A / cos
ϕ
= 1)
- integrated in the motor windings
- f.e. for fan controlling