Progressive Safety Gear
USG-25P
Operating Instructions
(
1
) Connect the contact
(
2
) Test the safety gear switch function - adjust
if necessary
(
3
) Adjust the switch horizontally on its fixing
bracket.
Adjusting dimension: 3-5 mm from the
guard peak
The contact must break just before safety
gear gripping!
3.6.1
Safety gear switch
-
utilization category:
AC-15
U
e
/I
e
240V / 3A
-
conv. thermal current:
I
the
= 10A
-
rated insulation voltage: U
i
= 250V AC
-
protection type:
IP 43
-
approved in accordance: DIN VDE 0470 T1
IEC/EN 60947-5-1
-
protection class:
II, totally insulated
(
1-3
)
Safety gear switch
3.6
Electrical installation of the
safety gear switch of housing
(type B)
Work involving electrical equipment
should only be carried out by an electrical
fitter or qualified personnel.
Before carrying out work, switch off all
voltage to installation equipment.
Take note of the following when laying
the connection cable:
• that the single polarity cables have
double insulation
• the use and laying of cables is governed
by the EMC
The safety gear contact opens the lift in -
stal lation’s remotely controlled safety cir-
cuit.
23
24
11
12