38
www
.wittur
.com
Changes can be made without notice
PM.2.004923.EN - 811-000-000 SDS
©
DC-PWM Compatible · Edition 22 July 2020
Drive - Instruction Manual
15 UPGRADE FROM LMDC 2010/11 CONTROLLER
•
Eliminate the transformer 220/24 V with all its cables because the new SDS is fitted with an in-built switching transformer
•
Disconnect all the connectors on the controller to be substituted and connect them again to the new controller using the
connectors-adatpers Code nr. B066AATX; this way no wiring operation is necessary and the substitution is quick and easy.
•
If the connectors-adapters Code nr. B066AATX are not available: disconnect the wires from the old connectors and connect them
again following the correspondence given in the underneath table
•
Connect the 220 Vac input to the SDS controller by means of the feeding cable supplied code no. E066AAWX-A
•
Select option EMULATION LM-DC 2010 or EMULATION LM-DC 2011 from the Menu General Option (see
) or programm parameter 22 using the keys on the frontal panel (05 o 06, see also
“5.3 Programming Mode “PROG”” a pag.
).
•
Check the correct functioning
LM-DC 2010/11 TERMINALS
FUNCTION
SEMATIC SDS Rel. 3
DC COMPATIBILE
LS1
Photocell or similar devices 24 Vdc COM
15
LS2
Photocell or similar devices control input
23
3
Kc closing control
3
5
Ka opening control
5
15
COM 24 Vdc
15
6
Ra and Rc opening and closing slow down
COM
15
6
Ra and Rc opening and closing slow down
COM
15
11
Ra opening slow down Input signal
41
13
Ra and Rc opening and closing slow down
COM
42
16
La Opening limit switch input contact
(from the magnetic switch)
40
17
La Opening limit switch COM (from the
magnetic switch)
15
18
Lc Closing limit switch input contact (from
the magnetic switch)
39
19
Lc Closing limit switch COM (from the
magnetic switch)
15
+B
Auxiliary emergency power supply
+
-B
Auxiliary emergency power supply
-
9
Motor power
43
10
Motor power
44