26
www
.wittur
.com
Changes can be made without notice
PM.2.004923.EN - 811-000-000 SDS
©
DC-PWM Compatible · Edition 22 July 2020
Drive - Instruction Manual
•
Press the "OK" key to confirm levels logic settings
For the Digidoor Interface connection verify that:
INPUT
Ka
â
L
Kc
â
L
Kb
â
L
Kn
â
H (to verify if it’s needed)
OUTPUT
La
â
H (to verify if it’s needed an L - Low level logic)
Lc
â
H (to verify if it’s needed an L - Low level logic)
7.5.6 Option “Opening slow down delay to opening rest current” (Only for digidoor emulation)
This option allows the user to change the opening rest current delay from the opening slow down Ra signal.
The setted time starts from the Ra switch signal.
Select the desired time using keys
ã
and
ä
. Press OK at the end.
7.5.7 Option “Closing limit delay to closing rest current” (Only for digidoor emulation)
This option allows the user to change the closing rest current delay from the closing limit Lc signal.
The setted time starts from the Lc switch signal.
Select the desired time using keys
ã
and
ä
. Press OK at the end.
7.6 OPTION “RESERVED AREA”
•
Connect the handset to RJ45 connector
•
If necessary, using keys
ã
and
ä
choose the required language and confirm with the “OK” key
•
Using keys
ã
and
ä
run through the MAIN MENU and choose PROFILE SETTING
•
Press the “OK” key to confirm the option
•
On the display the following options are viewed:
−
FAST SETTING
−
REVERSING SYSTEM
−
ADVANCED SETTINGS
−
RESERVED AREA
•
Using keys
ã
and
ä
run through the menu “PROFILE SETTING” and choose the option RESERVED AREA
•
Using the “OK” key, confirm the option
After confirming the choice by pressing the “OK” key, a 5-code password is required on the display. This selection is reserved for factory
use only.
Use keys
á
and
â
to insert the codes; to select the required code and modify its value use keys
ã
and
ä
.