5.2.2 IP65 mounting options
Mounting material: 2 cylinder head screws with hexagon socket ISO 4762 - M 4
– 8.8
Required tool: Inner hexagonal bolt SW 3
For tightening torques, see chapter 9.1
5.2.3 IP65 installation space
The installation size must be sufficiently large.
A minimum distance of 25 mm on all sides of the drive amplifier must be provided.
5.2.4 IP65 mounting position
Any mounting position can be selected.
5.2.5 IP65 ventilation / cooling
Sufficient convection for cooling of the drive amplifier must be ensured at the installation
location.
To avoid overheating, closed installation sites with low volume flow are not suitable for
installation of the drive amplifier.
The drive amplifier is to be mounted on a flat, metallic surface.
5.2.6 IP65 Environmental conditions for vibration/shock
The drive amplifier fulfills the following specifications:
Vibration according to DIN EN 60068-2-6:2008
o
Frequency range 10 Hz
– 150 Hz
o
Acceleration: 5 g
Shock according to DIN EN 60068-2-27:2010
o
Shock form: semi-sinusoidal
o
Acceleration: 50 g
o
Shock duration: 11 ms