Instruction manual
Floodlight 5000
10
Ed. 2.01
– 12/2019
Article N
o
50108013001
Mount the bracket onto the case using
screws.
Tightening torques
The tightening torques for the floodlight at the
mounting bracket are as follows:
25 Nm
for two
–four modules
10 Nm
for one module.
9.4
Electrical connection
Electrical connections should only be handled by a qualified electrician.
DANGER
Electric shock hazard.
ATTENTION
Do not use heat-shrinkable tubing, as it might damage the screw connection.
REFERENCE
Make sure that a light switch is installed in the electrical supply line.
The electrical connection is only described for the versions 2x40 up to to 4x40 W.
The version 1x40 is supplied with 1.5 m connection cable.
Characteristic data
Nominal voltage
Nominal power
Wire cross-section
Cable diameter
100-240V AC, 50/60 Hz
1x40W to 4x40W corresponding to the number of modules
Max. 3x4mm
2
(max.3x AWG 11)
9-17mm (0.
35“ – 0.67“, cable gland M25)
7.5-14 mm (0.3
“ – 0.55“,cable gland 2x M20)
Required tools
Insulation stripping pliers, screwdriver.
Preparing the connection cable.
Strip the cable sheathing and insulation.
Phase (L), Neutral (N) and Protective Earth (PE)
conductors required.
1
2
10-20 [mm]
i
2
i
3
Содержание Floodlight 5000
Страница 1: ...Article No 50xxxxxx Ed 2 0 07 2019 P a g e 1 Keep the instruction manual always handy ...
Страница 21: ...Instruction manual Floodlight 5000 21 Ed 2 01 12 2019 Article No 50108013001 ...
Страница 22: ...Instruction manual Floodlight 5000 22 Ed 2 01 12 2019 Article No 50108013001 ...
Страница 23: ...Instruction manual Floodlight 5000 23 Ed 2 01 12 2019 Article No 50108013001 ...