background image

 

 

1. Before Use the Device 

Thank you for purchasing the 6PSDSC-IP-5000Pseries.   

This User Manual is written for operators/users of the 6PSDSC-IP-5000PMulti-Format 

Professional HDTV Processor to assist in installation and operation. Please read this user 

manual carefully before installation and use of the device 

 

For Your Safety 

This equipment is provided with a protective earthing ground incorporated in the power 

cord. The main plug shall only be inserted in a socket outlet provided with a protective earth 

contact. Any interruption of the protective conductor, inside or outside the device, is likely to 

make the device dangerous.   

Do not remove the covers of this equipment. Hazardous voltages are present within this 

equipment  and  may  be  exposed  if  the  covers  are  removed.  Only  NETKLA  trained  and 

approved service engineers are permitted to service this equipment. 

No operator serviceable parts inside. Refer servicing to NETKLA trained and approved 

service engineers.   

For  the  correct  and  safe  use  of  the  device,  it  is  essential  that  both  operating  and 

servicing  personnel  follow  generally  accepted  safety  procedures  in  addition  to  the  safety 

precautions specified in this manual. 

Whenever  it  is  likely  that  safety  protection  is  impaired,  the  device  must  be  made 

in-operative and secured against unintended operation. The appropriate servicing authority 

must be informed. For example, safety is likely to be impaired if the device fails to perform the 

intended measurements or shows visible damage. 

 

WARNINGS 

 

The mounting environment should be relatively dust free, free of excessive vibration and 

the  ambient  temperature  between  0 

  to  40 

.  Relative  humidity  of  20%  to  80% 

(non-condensed) is recommended. 

 

Avoid direct contact with water. 

 

Never place the equipment in direct sunlight. 

 

The  outside  of  the  equipment  may  be  cleaned  using  a  lightly  dampened  cloth.  Do  not 

use any cleaning liquids containing alcohol, methylated spirit or ammonia etc. 

 

For continued protection against fire hazard, replace line fused only with same type. 

 

Air intake for cooling is achieved via holes at the side of the device and the fans inside. 

The air flow should not be obstructed. Therefore, the device has to be placed on a flat 

surface, leaving some space at the sides of the device. 

 

When in operation, the internal temperature should not exceed the limit of 70 

Содержание 5000P-10x

Страница 1: ...6PSDSC IP 5000P Series PSDR 5000 42S2 CAM IP PSDR 5000 30S2 CAM Multi Format Professional HDTV Processor User Manual Ver 2 3...

Страница 2: ......

Страница 3: ...1 1 Status Menu 6 5 1 2 DVB S2 Menu 6 5 1 3 RSSI 7 5 1 4 Ethernet Menu 7 5 2 Outputs Menu 8 5 2 1 BISS Menu 8 5 2 2 CI Menu 8 5 2 3 Decoder 9 5 2 4 ASI1 11 5 2 5 ASI2 11 5 2 6 SDI 11 5 2 7 Mux 11 5 2...

Страница 4: ...tting 19 5 4 4 Ethernet status 19 6 FAQ 19 7 Specification 19 8 Accessory List 21 9 IPTV Configuration Quick Guide 22 9 1 How to receive a multicast or unicast stream 22 9 2 How to set the Unicast Mul...

Страница 5: ...ersonnel follow generally accepted safety procedures in addition to the safety precautions specified in this manual Whenever it is likely that safety protection is impaired the device must be made in...

Страница 6: ...ograms into IP format It can be monitored and set parameters easily with Ethernet management software Moreover it supports CVBS YPbPr BNC SDI HDMI AES_EBU output interface High transmission speed and...

Страница 7: ...of 100 240 Vac 10 6 at 50 60 Hz nominal Be sure the supply voltage is within the specified range POWER REQUIREMENT Input voltage 90 250 Vrms auto select Frequency 47 to 63 Hz Power 50 VA max 30 VA typ...

Страница 8: ...EMENT LAN port for software update ASI OUT2 Group2 ASI output port one for back up ASI2 IN ASI2 input port SDI2 SDI2 output port HDMI HDMI output port CVBS CVBS RCA output port L Audio R2 Group2 RCA a...

Страница 9: ...ght means power is OK TUNER LOCK Tuner lock indicator green light means signal is locked if there is no light which means no signal input or wrong parameters setting ALARM Alarm indicator LCD 2 20 cha...

Страница 10: ...splay package format and code rate if signal is not locked it will show Unlock ASI2 When signal from ASI2 input port is locked it will display package format and code rate if signal is not locked it w...

Страница 11: ...ernet connector is for receiving transport stream over IP The Ethernet connector has user configurable IP address network mask and default gateway These must be set to appropriate values for the netwo...

Страница 12: ...or Biss 1 Biss 1 Setup set Biss 1 password is required Biss E Setup set Biss E ID number and password are required 5 2 2 CI Menu There are two PCMCIA slots for inserting CAM for de encrypting program...

Страница 13: ...e the parameters of Video and Audio of the program decoded by AV decoder Status OK or Alarms indicates the status of the decoder You can use the ENTER key to check detailed information Source Press th...

Страница 14: ...w seconds after the program being selected the A V signal will be delivered to the related connectors on the back panel Video You can configure the video parameters of programs in this submenu Press t...

Страница 15: ...ort on the back panel Mux TS the transport stream comes from internal Mux functional block will be delivered to the ASI output port on the back panel The Mux TS is valid only when the Mux function blo...

Страница 16: ...rogram name which comes from the CI 4 xxxxx displays the program name which comes from ASI2 input 5 xxxxx displays the program name which comes from BISS De encrypted input On Program List sub menu on...

Страница 17: ...put CI De encrypted TUNER Mux TS note the Mux TS is showed only when the Mux function block is enabled and turned on Refer to section 5 2 7 and section 5 3 6 for how to set the Mux function block Afte...

Страница 18: ...n the channels Each channel could be configured independently Channel x x means the channel number Press ENTER key to go down to the sub menu There are 4 sub menus x Multicast IP Enter the IP address...

Страница 19: ...te control system such as the HDMS IP Address The IP address for the unit Network Mask The network mask for the subnet to which the unit is connected Gateway The gateway for the network to which this...

Страница 20: ...e operation you need reboot the unit to valid the configuration IP In the TS IP port is configured as input you can feed transport stream over IP into the unit The menu Ethernet will be showed under t...

Страница 21: ...set the number of the TS packages encapsulated in one UDP package The valid range goes from 1 to 7 Time to Live set the number of the routers over which the TS over IP can be transmitted The valid ra...

Страница 22: ...t to RTP the following options are valid 5 4 2 IP In IP in status you can check the IP In status of the unit in this option RTP UDP it will display the transport protocol Column FEC Row FEC it will di...

Страница 23: ...s 5 4 4 Ethernet status Link shows the link speed 6 FAQ 1 Why is there nothing in the LCD Answer Please check whether the power supply is connected well first If not insert it well and turn on the dev...

Страница 24: ...7Mbps PAL or 1 6Mbps NTSC Demodulation 16 32 64 128 256 QAM Tuner Bandwidth 6MHz or 7MHz or 8MHz Input frequency range 50 860MHz Digital signal Input level 15 15dBmV Input connector IEC Female 7 8MHz...

Страница 25: ...pply socket 3 pin inputs RS 232 1 9 pin D sub male for software update Max Data Rate is 115200bps TS IP TS over IP input output optional Management Network management system allowing parameter setting...

Страница 26: ...o the Main menu Inputs Ethernet 2 Set the IP address parameters for the IP hardware board Stream IP addr enter the IP address for this IP hardware board should be the same network section of the Strea...

Страница 27: ...Unicast Multicast output please follow the procedure below 1 Go to the Main menu Outputs Ethernet 2 Set the IP address parameters for the IP hardware board Stream IP addr enter the IP address for thi...

Страница 28: ...er to go to the submenu As below Max Channels set the quantity of multicast unicast channels Channel 0 set the private parameters for Multicast Unitcast channel 0 Press Enter to go to the submenu 0 Un...

Отзывы: