Factory Reset
To reset the GWAY-1100 to factory defaults:
1. Be certain power has been removed from the GWAY-1100
2. Remove the lid of the GWAY-1100 by unscrewing the four corner screws
3. Once lid is removed, with connector panel positioned towards you, locate the two plated
drill holes in the upper center of the PC board
with the word “RESET” above it (P2)
. See
photo below.
4. Apply power to the GWAY-1100
5. Using an appropriate tool (twee-
zers, paper clip, etc.) short these
two pads together until the green
LED stops flashing and stays on
solidly.
6. Remove the short and replace the
top cover. Once you have removed
the short from P2, the reset will take
less than four seconds to complete.
Once reset, the following configuration el-
ements will be returned to their factory set-
tings:
Device Name: GWAY-1100
Host Name: SENSINET
DHCP Enabled. In the event that a DHCP server is available on the network, the follow-
ing will be provided automatic configuration data:
IP Address: DHCP assigned
Gateway: DHCP assigned
Subnet Mask: DHCP assigned
Primary DNS: DHCP assigned
Secondary DNS: DHCP assigned
If there is no DHCP server, an internal IP address will be provided. More infor-
mation about this process can be found in the Setup section of this manual.
User Name: admin
Password: Sensinet