More information for set up NP-14E as Com Port or TCP/IP   

 

1.

 

To set up NP-14E as com port in the local network. 

 

First use the NPort software to search the NP-14E 

https://drive.google.com/file/d/16cwU54jzU_omOCnnhGUaX6ZHkG9Xmsxz

/view?usp=sharing

 

 

 

And there is IP address for the NP-14E(in this example 192.168.0.29) 

Then open the IP address in the browser. 

If required password (the password is “moxa”) 

 

 

 

Under Basic Setting/Operation Modes choose “Real Com” and click on 

Submit/save and restart. 

Back to the NPort software and click on OK and yes.   

Содержание NetPage NP-14 Series

Страница 1: ...1 NetPage Network Wireless Paging System POCSAG NP 14 Series Operation Manual CCW152231 001 ...

Страница 2: ...e NP 14 inside encoder contents which are the capcode speed and message Etc can be sent by the tone only numeric 4 bit alphanumeric 7 bit using the POCSAG paging protocol out from either the serial port or from the Ethernet port The NP 14 option selection also has 8 ON OFF contacts for the alarm paging applications Each input is an independent port control for the contact input status either from ...

Страница 3: ...Ethernet LED indicate Yellow on for power ON Yellow flash for Net 10M link Green flash for 100M link 4 RS 232 Serial port Pin 2 TX data output To PC DB 9 Pin 2 RD Pin 3 RX data received From PC DB 9 Pin 3 TD Pin 5 GND required to PC DB 9 pin 5 5 Mini USB for the System programming 6 RF output to antenna or RF amplifier ...

Страница 4: ...e programming the NP 14 DC plug must be off and disconnected Just use the DC power source from the PC USB Tips to set up the programming parameters 1 Install the programming AP execution file 2 Click PMX NP and then runs the programming software 3 Connect the USB plug into your device and the PC USB port If show Disconnect Check USB Jack again ...

Страница 5: ...t power adjustment C FSK Deviation Frequency Deviation set up Normal 4 0K or 4 5K Max for POCSAG or 2 level data rate D Modulation type select Frequency modulation set up Normal 2 FSK 2 level FSK for POCSAG E Data Polarity Data Polarity in Normal or Invert set up Normal 01010101 Invert 10101010 General select Normal F POCSAG Preamble Preamble for pager power saving Normal set 576 bits or more G Pa...

Страница 6: ...G data speed and baud rate in 512bps or 1200bps Must be same as pager speed J Pager alert tone Pager alert tone select A 1beep per Sec B 2beeps per Sec C 3beeps per Sec D 4beeps per Sec K Pre program Message Pre programmed Message All ASCII words L Paging repeater Repeater call times for each paging 1 1 call 2 2 time call 3 3 time call 4 4 time call M Buzzer On off select NP 14 TX Buzzer On or Off...

Страница 7: ... SCOPE TAP Comp1 Comp2 GACOMP2 Select 1 to meet your console protocol T Number of alarm input Select alarm input option 8 input or 16 input The NP 14 default is 8 alarm input only U Alarm Trig switch level Select Alarm switch from NC to NO for action or NO to NC for action or any both Release Normal close to open Press Normal open to short Both Normal close to open and Normal open to close for ala...

Страница 8: ... activation more time is allowed for the next alarm action If under 1 sec will be no action X X for Rea Reading the programmed contents from your devices W W for Write Write the programming contents into your devices ...

Страница 9: ... way female PIN SIGNAL DIRECTION DB9 View looking into female connector NP 14 side 1 N C 2 RECEIVE DATA RX IN 3 TRANSMIT DATA TX OUT 4 N C 5 GROUND GND 6 N C 7 N C 8 CLEAR TO SEND CTS IN Link by RS 232 Plug the RS 232 Cable into an available DB9 serial port connector on the back of a Host Device such as a PC or Nurse Call system or other Host Device If the serial port has a DB25 connector you must...

Страница 10: ...10 Option serial RS 232 cable Part NO 86852933 00 ...

Страница 11: ...or tone C D for tone D Hello World message word Protocol Format Error Respond If the first character other than A or N Invalid Command format1 CR LF capcode fields appear with letter of alphabet Invalid Command format2 CR LF capcode 8 2097151 Capcode over range CR LF message type field appears character out of the ABCD Invalid Command format3 r n message has the invisible character Invalid Command...

Страница 12: ...12 ...

Страница 13: ...R is RF data rate where 5 represents 512 bps 1 represents 1200 bps and 2 represents 2400 bps d F is 0 1 2 3 or 4 defines the function code to be delivered It is 0 represent the default value for F is 4 when the E value is alphanumeric and 1 when the E value is numeric Numeric message 0 to F Hex that transfer to visible ASCII code is 30H to 39H 0 9 and 41H to 45H A F Message content any message you...

Страница 14: ...accept to transmitter then transmitter send CCCC ACK 06H to PC the CCCC is check sum of message if command did not accept to transmitter will not send back CCCC ACK 06H within 200 mS Note Transmitter encoder message must be based on two conditions as below Then it can encode all messages and send out all messages at one time 1 PC send message then receive the ACK from transmitter and PC send first...

Страница 15: ...ntacts alarm input PIN SIGNAL DIRECTION Header 2x8 View looking into connector NP 14 side 1 Alarm contact 1 input 2 Alarm contact 2 input 3 Alarm contact 3 input 4 Alarm contact 4 input 5 Alarm contact 5 input 6 Alarm contact 6 input 7 Alarm contact 7 input 8 Alarm contact 8 input 9 16 Ground Each alarm switch NO to NC or NC to NO be alarm active More switch of alarm input information ...

Страница 16: ...16 Option for ext trig wires Part No 86864528 00 Alarm switch or alarm sensor direct connection with wires ...

Страница 17: ...17 Option for ext trig alarm terminal board Part No 86864700 00 Use ext terminal board into the NP 14 Ext trig port ...

Страница 18: ...L2 Alarm 2 in S Trigger G Ground 3 AL3 Alarm 3 in S Trigger G Ground 4 AL4 Alarm 4 in S Trigger G Ground 5 AL5 Alarm 5 in S Trigger G Ground 6 AL6 Alarm 6 in S Trigger G Ground 7 AL7 Alarm 7 in S Trigger G Ground 8 AL8 Alarm 8 in S Trigger G Ground Each contact G S open to short or short to open be alarm active ...

Страница 19: ...19 The alarm cable can be in out on side hole of NP 14 ...

Страница 20: ...ng System Ethernet IP set up Guide Table 1 4 RJ 45 ETHERNET PORTS 8 pin receptacle PIN SIGNAL DIRECTION Click Click to install NPort RJ 45 View looking into receptacle NP 14 side 1 TD 2 TD 3 RD 4 NA 5 NA 6 RD 7 NA 8 NA ...

Страница 21: ...21 Click Next Click Next ...

Страница 22: ...22 Clock Install Click Finish ...

Страница 23: ...23 Click your PC start then click Nport Click ...

Страница 24: ...24 Click Search To find a IP address ...

Страница 25: ...25 Click OK Click Yes Waiting ...

Страница 26: ...26 NPort is ready ...

Страница 27: ...ps drive google com file d 16cwU54jzU_omOCnnhGUaX6ZHkG9Xmsxz view usp sharing And there is IP address for the NP 14E in this example 192 168 0 29 Then open the IP address in the browser If required password the password is moxa Under Basic Setting Operation Modes choose Real Com and click on Submit save and restart Back to the NPort software and click on OK and yes ...

Страница 28: ...28 Now the N 14E can be connected as Com port For example using Hterm software https www der hammer info pages terminal html Set connection 9600 8 n 1 Using Scope Protocol send on enter CR ...

Страница 29: ...ort software to search the NP 14E https drive google com file d 16cwU54jzU_omOCnnhGUaX6ZHkG9Xmsxz view usp sharing And there is IP address for the NP 14E in this example 192 168 0 29 Then open the IP address in the browser If required password the password is moxa ...

Страница 30: ...g choose for example TCP server And click on Submit save and restart And using TCP IP terminal software ex Packetsender https packetsender com Using the Message type Scope protocol follow by r Same method goes with UDP mode ...

Страница 31: ...connection IF RF power under 2 W the NP 14 antenna can be used by the rubber wipe antenna IF RF power over 2W the NP 14 must use the external antenna which must be Set at least 1 5 meters away from the NP 14 unit to avoid the interference Mount Mount on the wall by screw max 5 mm 66 mm ...

Страница 32: ... POCSAG Deviation 3 5 4 5Khz Stability 10ppm RF output power 0 1 7 W programmable 0 1 4 W programmable RF output connector BNC female SMA female option P C Interface USB 2 0 and RS 232 9600bps Ethernet RJ 45 TCP IP 10 100M Operation temperature 25 C 70 C Power Supply DC 12V 1A Minimum Size 120 mm X 110 mm X 25 mm Model Weight 0 8KGs include AC 100 240 to DC 12V 2A switching power adapter Notes Spe...

Отзывы: