Addendum
October 2021
1146200
SMI 2 User Guide
Rev. C
Page 33
Forced Operator Login
Figure 28
–
Forced Operator Login Settings
When Forced Operator Login is enabled a full screen message is displayed indicating that the operator
must login and the operator fields are erased from the SMI2. In addition, the SMI2 inhibit circuit will be
opened until an operator is logged in.
The Forced Operator Login feature can be enabled/disabled on the SMI2 additional settings screen. The
default state is disabled. This setting will be saved through power cycles.
Pressing the Operator
“
Login Expiration Time
”
button opens a keypad for numerical entry in
minutes. The default expiration time is 480 minutes (8 hours). This setting will be saved through power
cycles.
If the login timer expires the
“
Stop
on Expired Operator Login”
option, if enabled, will open the inhibit
circuit and display the operator login message for any state including Running.
Power cycles require the operator to login again and therefore reset the expiration timer.
Forced Operator Login will supersede the Forced Dialog Timer.