Figure 12 - Multipliers Menu
The Operations/Cycle should be used when one or more cycles of the machine are required
to produce a completed part.
The Cycle Count Multiplier value is the number of parts created after a single cycle.
The Rejects Count Multiplier value is the number of Scrap/Rejects that will be tallied and
deducted from the Good Parts Count when the Scrap/Rejects input is actuated.
Note: The Scrap input must be enabled to use this input. Often it is connected to an automated
scrap handling system or a simple N/C momentary switch for manual entry.
Enable ‘Stop
on
Total Parts Preset’ to open the SMI 2 Inhibit Relay and stop the machine when the
total quantity of items/parts have been reached.
Enable ‘Stop
on
Batch Preset’ to open the SMI 2 Inhibit Rel
ay and stop the machine when a batch
quantity of items/parts have been reached.
Note: Provided the machine’s stop circuit is wired in series the inhibit relay.
The ‘Reset Batch Count’ sets the Batch Segment Count to zero, not the Batch Segment Preset.