P A G E
|
7
Wintex Agro, Vilhelmsborgvej 15, DK-7700 Thisted
+45 97990800, [email protected], www.wintexagro.com
ADJUSTING THE PRESSURE OF THE SOIL SAMPLER TOWARDS THE GROUND
Open the lit of the electricity box.
Deactivate the emergency stop.
Adjust the Siemens logo:
Press “ESC”.
Press the downward arrow to “Set Param”.
Press ”Ok”.
Press the downward arrow until ”0n=”.
Move the cursor to change the numbers.
Larger numbers = higher pressure
Lower numbers = lower pressure
The pressure is from the factory pre-set at a proper pressure. Yet it might be necessary to adjust it
a bit so that the soil sampler stands firmly on the ground.
ADJUSTING THE ROTATION SPEED
Press the button down, and turn it counter-clockwise. The button will come up. Start the motor with
max. r.p.m. Press the main valve, and the probe will rotate.
Loosen the lock nut. The rotation speed is adjusted by turning the screw. When turning to the left, the
probe will move faster. When turning to the right, the probe will slow down. The adjusting screw must be
set to 50 r.p.m.
Press the button down. Turn it to the left so that it stays down.