Note that the data is only valid if both the BUSY and IN TER RUPT bits are both set to 1 in
the status reg is ter.
3.1.3
Base + 2 Address
Write Reg is ter - Start Con ver sion
D7 = N/A
D6 = N/A
D5 = N/A
D4 = N/A
D3 = N/A
D2 = N/A
D1 = N/A
D0 = N/A
A write to this reg is ter with any value will start the A/D con verter on what ever chan nel
was pre vi ously se lected by the Chan nel Se lect Reg is ter or the Chan nel Se lect/Start Con ver
-
sion reg is ter. This method of start ing the con verter al lows for maxi mum through put when
re peti tively con vert ing on the same chan nel as no mul ti plexer set tling time is re quired.
Read Reg is ter - MSB Data
D7 = D15 of con ver sion data
D6 = D14 “ ” “
D5 = D13 “ ” “
D4 = D12 “ ” “
D3 = D11 “ ” “
D2 = D10 “ ” “
D1 = D9 “ ” “
D0 = D8 “ ” “
Read ing from this reg is ter gives the up per 8- bits of the 16- bit con ver sion data. This data
is only valid if both the BUSY and IN TER RUPT bits are set to 1 in the status reg is ter.