CAS Write Cycle Width
Number of clocks CAS is high before a write. The available choices are :
1T
2T
3T
4T
CAS to RAS Read Delay
This op tion allows the number of clocks between CAS and RAS during a read. The
available choices are :
2 Cy cle
3 Cy cle
CAS Read 2 Cycle Precharge
This op tion, when en abled, adds 2 clocks to the second read.
AT Bus 0-Wait 8-Bit
This option, when disabled, adds 1 wait state, when enabled adds 0 wait states.
AT Bus 0-Wait 16-Bit
This option, when disabled, adds 1 wait state, when enabled adds 0 wait states.
AT Bus Hold
This option, when enabled, holds data for 1 clock cycle, disabled holds for 0 clock
cycles.
I/O Recovery
This option, when enabled, selects an I/O recovery time from the next 2 setup options.
The default is disabled.
8-Bit I/O Recovery Time
0.000 uS
021402
OPERATIONS MANUAL PCM-586
Page 3-14
WinSystems
- "The Embedded Systems Authority"