110502
PRODUCT MANUAL EPX-C380
24
The EPX-C380 has an integrated display controller that interfaces to both Analog VGA and flat panel displays. The video
output mode is selected in the CMOS setup. Simultaneous flat panel and Analog VGA mode is also supported. The
Analog VGA connector is located at
J1
. WinSystems offers the cable
CBL-VGA-002-12
to simplify the connection. The
LVDS interface connector is located at
J7
to interface to flat panels. A backlight power connectors is located at
J5.
Panel
power option selection is made at
JP1
.
Contact your WinSystems’ Applications Engineer for information about available cable kits and supported panels.
This manual does not attempt to provide any information about how to connect to specific LCDs.
Avoid Simultaneous Jumpering of pins 1-2 and 2-3.
Misjumpering panel power causes damage to the
board and/or the Flat Panel.
JP1 - Panel Power
Visual
Index
Panel Power
5V
3.3V (default)
2-3
1-2
□ □ □
3 2 1
JP1
Preliminary