SECTION 6
ELECTRICAL SYSTEMS
6-8
Stopping:
·
Before shutting generator down, turn off
electrical loads and let engine run at no-load
for a few minutes to cool down.
·
Press the generator switch Off and hold until
the generator engine comes to a complete
stop.
GENERATOR HOURMETER
This meter is located on the monitor panel.
(See photo on previous page.) It registers the
total number of hours that the generator has been
operated. Refer to the hourmeter to determine
when periodic maintenance is due and to record
services which have been performed.
GENERATOR OPERATION
WARNINGS AND CAUTIONS
4.
Do not
simultaneously operate the generator
engine and a ventilator which could draw
exhaust gases into the vehicle.
5.
Do not
open windows or ventilators on the
end or side of the vehicle where exhaust pipe
of the generator is located.
6.
Park the vehicle
so that the wind will carry
the exhaust away from the vehicle. Also,
note the position of other vehicles to be sure
their exhaust will not enter your vehicle.
7.
Do not
operate the generator engine when
parked if vegetation, snow, buildings, vehi-
cles, or any other object can deflect the
exhaust under or into the vehicle.
Check auxiliary generator oil level frequently
during periods of use. Refer to the generator
manufacturer’s information in your InfoCase for
specific recommendations.
Continuous generator overloading
can cause high operating tempera-
tures that can damage the generator
windings. Keep the electrical loads
within the generator wattage ratings.
Approximate Power Requirements of
Common Appliances
Appliance or Tool
Approximate Power
Consumption
(Watts/Amps)
Vacuum cleaner
Coffee Maker
Hair dryer
Electric clothes iron
Electric blanket
Television
Electric drill
Air conditioner
Converter
Microwave Oven
200-500W/1.7-4.3A
550-700W/4.8-6.1A
800-1500W/7.0-13.0A
500-1200W/4.3-10.4A
50-200W/0.4-1.7A
80-100W/0.7A
250-750W/2.2-6.5A
1400-2000W/13-19A
300-500W/2.6-4.3A
700-1500W/6.0-13.0A
CAUTION
The exhaust of all internal combus-
tion engines contains carbon monox-
ide (CO). This poisonous gas is
colorless, odorless, tasteless, and
lighter than air. The exhaust systems
of both your motor home engine and
your generator engine have been
installed with your safety in mind.
However, certain precautions must be
taken when using them to protect
yourself from conditions beyond the
control of the manufacturer.
Never check generator oil level while
generator engine is running.
WARNING
WARNING
Содержание Sunflyer
Страница 4: ......
Страница 10: ......
Страница 16: ......
Страница 54: ......
Страница 68: ......
Страница 90: ......
Страница 130: ......
Страница 140: ......
Страница 142: ...MAINTENANCE RECORD Date Odometer Mileage Description of Service Cost...
Страница 143: ...FUEL OIL RECORD Date Odometer Mileage Fuel Gal Oil Qts MPG Cost Date Odometer Mileage Fuel Gals Oil Qts MPG Cost...
Страница 144: ...FUEL OIL RECORD Date Odometer Mileage Fuel Gal Oil Qts MPG Cost Date Odometer Mileage Fuel Gals Oil Qts MPG Cost...