SECTION 8
APPLIANCES & INTERIOR FEATURES
8-10
For Quick Recovery Operation (Dual):
Turn On both Water Heater switches; the gas one
on the monitor panel and the electric one. This
will help reheat the water heater tank more
quickly than a single source would alone. Use
this mode when you are using a larger than nor-
mal volume of hot water, for example, when
someone is taking a shower and the dishwasher
or clothes washer is also being used.
Gas Safety Information
A. This appliance does not have a pilot light. It
is equipped with an ignition device that auto-
matically lights the burner. Do Not try to
light the burner by hand.
B. Before lighting, smell around the appliance
area for gas. Be sure to smell near floor
because LP gas is heavier than air and will
settle on the floor.
WHAT TO DO IF YOU SMELL GAS
•
Do not try to light any appliance.
•
Do not touch any electrical switch.
•
Get out of the coach immediately and turn
off the LP gas tank at the main tank valve.
(See photo on page 5-2.)
•
Use a neighbor’s phone to call your Win-
nebago Industries dealer or a local gas sup-
plier for instructions. Do not use a phone in
your coach. Follow the dealer’s or gas sup-
plier’s instructions.
•
If you cannot reach a Winnebago Industries
dealer or a local gas supplier, call the fire
department.
•
Have the source of the leak corrected before
using the LP gas system again.
Operating Instructions
1. STOP! Read the safety information provided
in the Atwood Water Heater Operation Man-
ual in your Owners InfoCase.
2. Turn off water heater power switches.
3. Turn LP gas supply off.
4. Wait five minutes for any gas to clear the
area. If you smell gas, then stop and follow
item B of the Safety Information above. If
you don’t smell gas, go to the next step.
5. Turn on LP gas main tank valve.
6. Turn on the water heater switch on the moni-
tor panel. You may hear a clicking noise as
the ignition element begins working. If the
burner does not light on first try, the system
will stop trying to light burner and go to
lockout mode.
7. If lockout happens before main burner lights,
turn switch OFF, wait five seconds and turn
switch back on. This will restart the ignition
cycle. The first start-up of the water heater
after it has not been used for a long time may
require several ignition cycles before all the
air is purged from the gas lines and gas
begins to flow.
If the burner will not come on, check the fol-
lowing items before calling for service.
1. Is the switch turned on?
2. Does the LP tank have gas in it or is main
tank valve turned on?
3. Is the ECO Reset button tripped? (See
Atwood Water Heater Operation Man-
ual
in your Owners InfoCase.)
To Turn Water Heater Off
1. Turn switch on monitor panel to Off posi-
tion.
2. Turn electric water heater switch off.
3. Turn off LP gas supply (if not to be used for
extended period).
Содержание Sunflyer
Страница 4: ......
Страница 10: ......
Страница 16: ......
Страница 54: ......
Страница 68: ......
Страница 90: ......
Страница 130: ......
Страница 140: ......
Страница 142: ...MAINTENANCE RECORD Date Odometer Mileage Description of Service Cost...
Страница 143: ...FUEL OIL RECORD Date Odometer Mileage Fuel Gal Oil Qts MPG Cost Date Odometer Mileage Fuel Gals Oil Qts MPG Cost...
Страница 144: ...FUEL OIL RECORD Date Odometer Mileage Fuel Gal Oil Qts MPG Cost Date Odometer Mileage Fuel Gals Oil Qts MPG Cost...