6-11
SECTION 6 –
PLUMBING
5.
Empty the water pump strainer filter bowl
to avoid water freezing and cracking the
filter bowl.
(located below the Water Center
Panel)
6.
Connect Air Pressure.
Connect a “blow-out”
plug to the city water inlet (located on the
lower left of the Water Center Panel). Then,
use a compressed air hose regulated to 30 psi
or less to force air through the system.
A “blow-out” plug can be purchased at any
Winnebago Industries
®
dealer.
NOTE: DO NOT burst air into the system. This
can damage the water pump. It is better
to let air in slowly.
7.
Drain Exterior Shower/Wash Station.
Attach exterior shower hose, then point
shower hose toward ground and squeeze the
handle. Turn on the hot faucet, then the cold to
drain any water left in the shower and sink
lines.
NOTE: The exterior wash station detachable
hose is stored behind the rear driver’s
side door, in the left storage
compartment
.
Water Pump
(Located below Water Center Panel - remove
panel to access)
-Typical View
To Clean Pump Strainer
•
Twist the inlet cap (bowl)
“counter-clockwise” to
unscrew from the strainer
assembly.
•
Remove the bowl and pull
the strainer screen out of
the bowl to tap out any
particles and rinse clean.
•
Insert the strainer screen
back into the bowl, then
screw the bowl back onto
the strainer assembly.
-Typical view
NOTICE
Limit air pressure to 30 psi to avoid
damage to equipment.
City Water
Connection
Fresh Water
Inlet
Blow-out
Plug
Air Hose