COMMODORE
COMMODORE
PROBLEM
No
electrical power.
Loss
solution recovery.
No
forward movement
of
machine.
No
solution flow.
Solution will not
off.
cleaning.
CAUSE
Dead
electrical circuit.
Faulty
main
power switch
on
machine.
Faulty power cord.
Fuse blown
or
circuit breaker tripped
(on
machine).
Vacuum lever
in
"off" position.
Faulty
motor
switch.
Worn
motor brushes
or
faulty
motor.
Crack
in
recovery dome.
Obstruction
or
damage in
shoe linkage
or
hose.
Incorrectly installed
or
adjusted
shoe.
Loose wires at switch
or
connections.
Faulty drive
motor switch.
Worn
carbon brushes in gear drive motor
or
faulty motor.
Fuse blown
or
circuit breaker tripped
(on
machine).
Faulty speed control potentiometer.
Faulty pump.
Faulty switch.
"Clogged"
or
faulty solenoid.
Obstruction in jets.
Faulty switch.
in solenoid valve or faulty valve.
One
or
more jets plugged.
SO
N
Check building circuit breaker
or
fuse box.
Replace switch.
Repair
or
replace power
cord,
fuse
or
reset
breaker
after
problem.
Put
lever
in
"on"
position.
Replace switch.
Replace motor brushes
or
motor.
Repair
or
replace.
Remove obstruction, repair or replace
casting.
Adjust
shoe.
Repair as required.
Replace switch.
Replace fuse
or
reset breaker after
correcting problem.
Replace control.
Replace pump.
Replace switch.
Remove obstruction
or
replace.
Remove and clean jets.
Replace switch.
Remove obstruction
or
replace valve.
Clean jets.
19
Содержание COMMODORE CMD
Страница 11: ...COMMODORE 115V CONTROL PANEL ASSEMBLY I COMMOOOAE CONTROL PANEL ...
Страница 12: ...2 CHASSISWIDRIVE ASSEMBLY ...
Страница 14: ...COMMODORE 1 15V 14 ...
Страница 16: ...COMMODORE 115V SQtUTION RECOVERY TANKS 16 ...
Страница 18: ...COMMODORE 115V CONTROL PANE1 WIRING DIAGRAM 230VOLT CHASSIS WIRING DIAORAM 230 VOLT A I8 i 18 ...