Quick guide
VarioWIN pellet central heating boiler
Operating phases are displayed
here, including Standby, Burner
OFF, etc.
Menu line
Signal lamp (LED)
„Operation“ – green
Full-text display
(illuminated display)
Assignment of buttons to
their specific function
Manual operation / flue cleaning
function
ON/OFF button
Menu buttons
5s
RESET
Boiler temperature
Standby
Info
Menu
38
°C
07/2012
092948/02
Ending function: Press the
Cancel
button or automatically after about 45 minutes.
Chimney sweeper func.
Power 100%
45 min
(Operating phases)
30%
Cancel 100%
42
°C
(Symbol flashes)
Chimney sweeper func.
Power 30%
45 min
(Operating phases)
30%
Cancel 100%
42
°C
(Symbol flashes)
Pressing the corresponding
menu
button enables the boiler to be operated with 30 % (= part load) or 100 % output.
The operating time is reset to 45 min. when the
Manual operation / chimney sweeper
function button is pressed
again.
Chimney sweeper function
Starting: Briefly press the
Manual operation / chimney sweeper
funktion button (the lighting/display is switched
on), press the button again briefly, the boiler temperature is set to about 60 °C for 45 min.
Removing ash and cleaning boiler and burner
Note!
The ash may be loaded with heavy metals. Heavy metals may affect soil fertility. Ash is not there-
fore suitable as a fertiliser and should be disposed of with residual waste.
Warning of hot surface: risk of burns!
Before touching these surfaces, you must switch off the boiler and let it cool.
Attention!
Do not open the combustion chamber door during operation. Always switch the boiler off first with
the ON/OFF button and wait until burnout mode has finished.
Risk of fire if ash hasn‘t cooled! Store ash in lockable and non-combustible container on non-
combustible base for at least 48 hours.
InfoWINplus
The lighting/display is initially switched on for 10 min. by briefly pressing a button. The corresponding function is
then started by pressing the button again.
A brief explanation of the most important functions of the operating unit: