EN
141
Overview
Installation
Use
Maintenance
Warranty
8. Electrical connection
Refer to the electrical wiring diagram on the next to last page.
Never power the heating element directly.
The water heater can only be turned on after it has been filled with water.
The water heater must be permanently powered by electricity.
The water heater can only be connected and operated on a single-phase 230V AC grid. Connect the water
heater using a rigid cable with 1.5 mm² conductors. The installation will include:
•
An omnipolar 16A circuit breaker with a contact opening of at least 3mm,
•
Protection by a 30mA differential circuit breaker.
If the power cable is damaged, it must be replaced by the manufacturer, their after sales service or a similarly
qualified person, in order to avoid any danger.
The safety thermostat fitted to the electric heater must under no circumstances be repaired by anyone other
than our service staff.
Non-compliance with this clause will void your warranty.
The appliance must be installed in accordance with the national regulations concerning electrical
installations.
3 x 1,5mm²
16A
The ground connection is mandatory.
Electrical connection diagram
m²
Содержание AquaWIN Air 203
Страница 16: ...14 5 Unzul ssige Einbauarten Beschreibung Installation Einsatz Wartung Garantie...
Страница 82: ...80...
Страница 122: ...120...
Страница 162: ...160...
Страница 163: ......
Страница 164: ...U0640027 D Imp Signatures Graphiques F 68360 Soultz...