140
Overview
Installation
Use
Maintenance
Warranty
7.2. Adjustment of inlet and outlet vent direction.
❶ Unscrew the vents'
locking
screws
and
rotate them to select
the required direction
❸
Turning
them
another
120°
points
them towards the sides.
❷ Turning them 120°
points them backwards.
Note:
The directional vents can reduce or eliminate the use of ducting elbows. For more information on
directional vents, see "Positioning the product".
❹ Do not point the
vents
towards
each
other.
Configuration prohibited
because
of
the
recirculation of cold air
in the device!
-
-
Standard configurations
x 2
Roof
Lengths
Max.
L1 + L2
Semi-rigid galvanised
duct Ø160mm
7.1. Lengths of permitted ducts.
Exterior/Exterior ducting
Air Outlets/Inlets
HDPE duct Ø 160 mm
12 m
28 m
Wall Roof
12 m
26 m
x 2
Wall
5 m
16 m
Roof Wall
10 m
24 m
Содержание AquaWIN Air 203