background image

INTRODUCTION

Th ank you for selecting the Wind & Weather Wireless 

Rain and Temperature Monitor. Th is device monitors 

and displays rainfall data along with the indoor/out-

door temperature from up to three remote locations. 

In this package you will fi nd:

• One main unit (receiver)

• One remote rain gauge (transmitter)

• One remote temperature sensor (transmitter)

Please keep this manual handy as you use your new 

item. It contains practical step-by-step instructions, 

as well as technical specifi cations and precautions you 

should know.

PRODUCT OVERVIEW

MAIN UNIT—FEATURES

•  Wireless transmission of the rainfall data from the 

remote rain gauge to the main unit up to 100 feet (30 

meters) away

•  Wireless transmission of the temperature from the 

remote temperature sensor to the main unit up to 100 

feet (30 meters) away

• Rainfall may be displayed in inches or mm

• Programmable Rain Alarm

• 7 days of rain collection history

• Built-in rain gauge installation level

• Indoor and remote temperature display

• Min/Max Memory for indoor/outdoor temperature

• Hourly, daily and weekly rainfall history

• Monitors temperature in up to 3 remote locations

• Quartz clock with calendar

• Programmable Time Zones

•  Day of the week in English, German, French, Spanish 

or Italian

• Dual crescendo alarm with snooze

• Programmable Ice Warning Alarm

• Wall mount or desktop option

• Low battery indicator

• LED backlight

3

4

Содержание RG1736

Страница 1: ...Getting Started 15 Remote and Indoor Temperatures 16 Auto Scanning 16 Checking Remote Rainfall Data 17 Maximum and Minimum Temperature 18 Lost Communication 18 Transmission Collision 19 Calendar and Clock Display Modes 20 Manual Settings 20 Alarms 21 Snooze 23 Precautions 23 Specifications 24 FCC Statement 26 Declaration of Conformity 27 Standard Warranty Information 28 Wireless Rain and Temperatur...

Страница 2: ...of the rainfall data from the remote rain gauge to the main unit up to 100 feet 30 meters away Wireless transmission of the temperature from the remote temperature sensor to the main unit up to 100 feet 30 meters away Rainfall may be displayed in inches or mm Programmable Rain Alarm 7 days of rain collection history Built in rain gauge installation level Indoor and remote temperature display Min M...

Страница 3: ...t 7 days Increases all function parameters press and hold for rapid increase Enables or disables rain alarm E DOWN button Toggles between the rainfall modes for past hour for the past 24 hours and for the past 7 days Decreases all function parameters press and hold for rapid decrease Enables or disables high rain alarm Enforces the remote rain gauge signal search F MEMORY button Toggles between th...

Страница 4: ...les remote temperature channels auto scanning feature N SNOOZE LIGHT button Enables backlight for 5 seconds Stops any alarm temporarily O BATTERY COMPARTMENT Uses 2 two UM 3 or AA 1 5V alkaline batteries P WALL MOUNT RECESSED HOLE Keeps the main unit on the wall Q REMOVABLE TABLE STAND Keeps main unit in upright position on a flat surface REMOTE RAIN GAUGE FEATURES Precipitation measurement Remote ...

Страница 5: ... Remote temperature transmission to the main unit via 433 MHz signal 100 feet 30 meters transmission range without interference LCD display of measured temperature Three transmission 3 channels selection Selection of the temperature display in C or F Case can be wall mounted using built in hanger A LED INDICATOR Flashes once when the remote temperature sensor transmits a reading to the main unit F...

Страница 6: ... and trees It is important that excess precipitation can freely flow from the remote rain gauge The remote temperature sensor can be placed indoors or outdoors depending on the area where the tem perature is intended to be measured The main unit must be placed indoors NOTE 1 Avoid pressing any buttons on the main unit before the remote rainfall and temperature data is displayed 2 The effective opera...

Страница 7: ...to the gauge s bucket ideally 2 3 feet above the ground BATTERY INSTALLATION REMOTE TEMPERATURE SENSOR NOTE Install the batteries select the channel and temperature in C or F before mounting the remote temperature sensor Remove the screws from the battery compartment with a small Phillips screwdriver Set the channel The switch is located in the battery compartment Channel 1 is typically selected i...

Страница 8: ...remote rainfall Press and hold the back panel DOWN button on the main unit for two seconds to initiate a signal search for the remote temperature REMOTE AND INDOOR TEMPERATURES The remote temperature information is located on the middle line of the main unit s display The indoor tem perature with the icon IN is located next to the remote temperature The wave icon above the remote channel number in...

Страница 9: ...t is in searching mode Rainfall readings are securely registered No signal MAXIMUM AND MINIMUM TEMPERATURE The maximum and minimum record of the indoor and remote temperatures will be automatically stored in the memory of the main unit To display the minimum maximum or the current reading press MEMORY button on the back panel To clear the memory press and hold MEMORY button on the back for two sec...

Страница 10: ...curity systems and entry control may interfere with this product or cause temporary reception interruption This is normal and will not affect the general performance of the product The transmission and reception of the remote readings will resume once the interference subsides CALENDAR AND CLOCK DISPLAY MODES Date is displayed in month date or date month format Each press of the MODE button on the ...

Страница 11: ...day alarm is activated it will sound at the set time and the alarm icon will flash only for this specific day and will not activate on subsequent days If Ice Warning alarm is activated in will sound at the set time and alarm icon will flash if the remote temperature for Channel One 1 reaches 35 6 F 2 C and below NOTE Ice Warning Alarm can be set only if one or both of the Weekday or Single alarm are ...

Страница 12: ...are a few precautions Do not immerse the units in water Do not clean the units with abrasive or corrosive ma terials They may scratch the plastic parts and corrode the electronic circuits Do not subject the product to excessive force shock dust temperature or humidity which may result in malfunctions shorter lifespan damaged batteries and damaged parts Do not tamper with the units internal compone...

Страница 13: ...es not included Dimensions Main unit 2 W x 5 H Remote sensor 2 W x 4 H Remote rain gauge 6 W x 7 H FCC STATEMENT This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired opera tion Warning Changes or ...

Страница 14: ...es Hong Kong is in conformity with Part 15 of the FCC Rules Opera tion is subject to the following two conditions 1 This device may not cause harmful interference 2 This device must accept any interference received including interference that may cause undesired opera tion STANDARD WARRANTY INFORMATION This product is warranted from manufacturing defects for one year from date of retail purchase I...

Отзывы: