DC24V (Mo du lar Prin ter)
Appropriate POS printers can be connected via the low-voltage jack 24V,
max. 3A via non-UPS. A connecting cable with a HOSIDEN plug is required
for this.
Connect only cables to the 24V connector which are marked with DP-1 or
DP-2.
Do not connect the HOSIDEN plug when the system is turned on, this can
lead to an automatical reboot of the system.
RJ12 (CASHDR, Geld la de)
The power supply unit has one RJ12 socket for connecting a cash drawer.
Make sure that the connector is plugged firmly into the socket to prevent
malfunctioning. RJ12 plugs lock in when you insert them. Power is supplied
to the cash drawer via this socket, P24V +5% / -15%.
Connecting daisy chained cash drawers and 12V OEM-drawers is
prohibited!
Connect cash drawers only (no telephon).
POWER SUPPLY