background image

3225-00

60706-241

DESCRIPTION

The WINCO rotating field power take-off generators are de

-

signed primarily for hobby/small farm use as a standby electrical 

power supply, utilizing the power take-off of a tractor or truck 

as the prime mover.  This PTO drive generator will provide 

120/240V single phase, 60Hz electrical service when properly 

driven.

NOTE: 

The prime mover which drives the generator must be 

capable of delivering approximately 2 HP per 1000 watts output 

from the generator. Observe input RPM specifications.

This generator may be mounted in many different fashions.  The 

three most popular are foundation mounted,  trailer mount or 3-

point hitch mounted, for used as a standby or portable electrical 

power source.  Your application will dictate how you may want to 

mount it.

This generator includes a color coded voltmeter to warn against 

high or low voltage, and two output power receptacles with 

individual circuit breakers for your protection. To reduce mainte-

nance problems, the coupling between the generator input shaft 

and rotor consists of precision helical gearing rather than a chain 

link drive. The input shaft is a 1 3/8 in. diameter 6 spline shaft.

The factory thoroughly tests each generator before shipment. All 

are continuous duty rated.

IMPORTANT: 

THE MANUFACTURER STRONGLY RECOMMENDS RUN-

NING THE GENERATOR UNDER LOAD AT LEAST ONCE A 

MONTH IN ORDER TO EVAPORATE ANY ACCUMULATED 

MOISTURE CONDENSATION AND TO KEEP THE UNIT IN 

GOOD WORKING ORDER.

SPECIFICATIONS

Model Number   

 

W10PTOS/

Wattage  

 

 

 

10000

Amperage   

 

 

42

Input Speed   

 

 

515 RPM

Generator Speed  

 

3600 RPM

Input Shaft   

 

 

1 3/8” - 6 spline 

Tractor PTO Hp Required  

20

Gear Lube

 

Volume   

 

 

16 ounces

 

Type 

 

 

 

85/90W-140

 

 

Features 

*   Brushless, low harmonic design with skewed rotor and  

 

 

damper windings for minimal load noise

*   Capacitor Excitation

*   Dual voltage - 120/240 volt output

*   4 wire Load connection plug for convenient full load 120/            

 

240 volt output cord set

*   15 Amp duplex convenience receptacle

*    Large face Voltmeter for proper speed setting and 

 

adjustment 

UNPACKING

CAUTION:  Equipment Damage

DO NOT invert generator during unpacking. The Gearcase con-

tains oil which will leak out if inverted during unpacking.

Unpack the generator as follows:

1.   Remove the carton.

2.   Examine the unit for damage.

3.   Find the small subpack carton packed in the large car-

ton.  Be careful not to throw away the subpack carton 

with the large carton.

4.   Open the subpack carton and make sure it contains:

 

a.   Generator instruction manual

 

b.   Load disconnect plug (disassembled, in bag)

5.   Remove the four bolts which hold  the generator feet to 

the pallet.

6.   Lift the generator from the pallet by means of the lifting 

eye on the top of the generator.

7.   Inspect the generator carefully for freight loss or dam-

age. If loss or damage is noted at time of delivery, 

require that the person making the delivery make note 

of the loss or damage on the freight bill, or sign the 

consignee’s memo of the loss or damage. Contact the 

carrier for claim procedures.

When loss or damage is noted after delivery, segregate the dam-

aged material, and contact the carrier for claim procedures.

“Concealed damage” means damage to the contents of a pack-

age which is not evident when the package is delivered by the 

carrier, but which is discovered later. The carrier or carriers are 

responsible for merchandise lost or damaged in transit. The 

title to the goods rests with the consignee when the goods are 

shipped FOB factory, and only the consignee can legally file 

claims. Two years are allowed in which to file suit after a claim is 

disallowed in writing by the carrier.

INSTALLATION

FOUNDATION MOUNTING

Mount the generator on a foundation if it is to be used as a 

permanent or standby power source. See “TRAILER MOUNT-

ING” or “THREE POINT HITCH MOUNTING” if generator will be 

used as a portable power source. When planning a foundation 

consider the following points:

A.   The foundation location should enable aligning the drive 

shaft (tumbling bar) in a straight or nearly straight line between 

the power take-off and the generator input shaft. Misalignment 

must be less than 5 degrees during generator operation, even 

though the mechanical design of the tumbling bar would allow  

greater misalignment.

Содержание W10PTOS/A

Страница 1: ...COMPACT SERIES TRACTOR DRIVE GENERATOR W10PTOS A...

Страница 2: ...ser vice when commercial power is interrupted inaccessible or impractical This PTO unit has a cast iron gear case with a 1 3 8 6 spline 540 rpm rated input shaft unit operating speed is 515 RPM and b...

Страница 3: ...r nearby and know its proper use Fire extinguishers rated ABC by NFPA are appropriate 3 DEADLY EXHAUST GAS Exhaust fumes from any engine contain carbon monoxide an invisible odorless and deadly gas th...

Страница 4: ...and adjustment UNPACKING CAUTION Equipment Damage DO NOT invert generator during unpacking The Gearcase con tains oil which will leak out if inverted during unpacking Unpack the generator as follows...

Страница 5: ...ling bar C For safety the generator must be bolted to the three point hitch deck using all four mounting bolts B The foundation must be solid enough to absorb generator starting and reflected load tor...

Страница 6: ...INES FROM THE LOAD AND THE GENERATOR WHEN THE GEN ERATOR IS SUPPLYING POWER SEE FIGURE 6 Page 4 60706 180 0310 00 ELECTRICAL CONNECTIONS CAUTION Only qualified electricians should install electrical w...

Страница 7: ...OR TOO MUCH OIL CAN HARM THE EQUIPMENT See Lubrication portion of Main tenance for oil specifications Page 5 60706 180 0310 00 A properly rated and installed double throw manual power isolation transf...

Страница 8: ...e sure the drive shaft tumbling bar is assembled with its universal joint knuckles synchronized as illustrated in Figure 7 If knuckles are not synchronized the bar will chat ter when rotating which wi...

Страница 9: ...ING Equipment Damage DO NOT CLEAN THE GENERATOR WHILE IT IS RUNNING STORAGE MAINTENANCE If the generator is mounted on an off highway trailer such as the Winco trailer it should be stored in a garage...

Страница 10: ...t and replace if defective Low Speed High line loss Indicated by lower voltage at load than at generator terminals 1 Undersized overloaded 2 Defective governor 3 Low power worn engine LOW OUTPUT VOLTA...

Страница 11: ...11 3225 00 60706 241 ILLUSTRATED PARTS LIST COMPLETE ASSEMBLY...

Страница 12: ...w 7 300080 3 1 Top Cover 8 Z2568 1 Decal Danger PTO 9 300086 2 1 Drive Shaft Guard 10 98479 000 1 Decal Winco 1 11 53113 002 2 Decal Winco 12 63966 009 1 Nameplete 13 99841 003 1 Gear Case Support 14...

Страница 13: ...QTY DESCRIPTION 99839 002 1 Complete Generator End with Gear Case 19 54665 000 1 6205 2RS Bearing 26 300323 208 2 Varistor 27 300323 207 2 Diode 65 99839 112 1 45 mf Capacitor GENERATOR SPECIFICATIONS...

Страница 14: ...REF PART NUMBER QTY DESCRIPTION 1 300080 3 1 Top Cover 2 91286 001 1 20 Amp 1 Pole Circuit Breaker 3 63708 000 1 Ground Lug 4 57030 007 1 45 Amp 240 VAC Circuit Breaker 5 91370 000 1 Voltmeter 6 3000...

Страница 15: ...O WHEEL TRANSPORT DESCRIPTION PART NO 1 SUPPORT TONGUE QTY 2 300081 2 HITCH TONGUE QTY 2 300082 3 TONGUE 300083 4 AXLE QTY 2 300085 5 SUPPORT AXLE 300164 6 SUPPORT PTO SHAFT 300161 1 7 SUPPORT PTO SHA...

Страница 16: ...of incidental or consequential damages so that above limitation or exclusion may not apply to you This warranty gives you specific legal rights you may have other rights which vary from state to state...

Отзывы: